hv_netvsc: do not use VF device if link is down
If the accelerated networking SRIOV VF device has lost carrier use the synthetic network device which is available as backup path. This is a rare case since if VF link goes down, normally the VMBus device will also loose external connectivity as well. But if the communication is between two VM's on the same host the VMBus device will still work. Reported-by: "Shah, Ashish N" <ashish.n.shah@intel.com> Fixes: 0c195567a8f6 ("netvsc: transparent VF management") Signed-off-by: Stephen Hemminger <stephen@networkplumber.org> Reviewed-by: Haiyang Zhang <haiyangz@microsoft.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/hyperv')
-rw-r--r--drivers/net/hyperv/netvsc_drv.c7
1 files changed, 4 insertions, 3 deletions
diff --git a/drivers/net/hyperv/netvsc_drv.c b/drivers/net/hyperv/netvsc_drv.c
index d27b90b4e2bb..787f17e2a971 100644
--- a/drivers/net/hyperv/netvsc_drv.c
+++ b/drivers/net/hyperv/netvsc_drv.c
@@ -532,12 +532,13 @@ static int netvsc_xmit(struct sk_buff *skb, struct net_device *net, bool xdp_tx)
u32 hash;
struct hv_page_buffer pb[MAX_PAGE_BUFFER_COUNT];
- /* if VF is present and up then redirect packets
- * already called with rcu_read_lock_bh
+ /* If VF is present and up then redirect packets to it.
+ * Skip the VF if it is marked down or has no carrier.
+ * If netpoll is in uses, then VF can not be used either.
*/
vf_netdev = rcu_dereference_bh(net_device_ctx->vf_netdev);
if (vf_netdev && netif_running(vf_netdev) &&
- !netpoll_tx_running(net))
+ netif_carrier_ok(vf_netdev) && !netpoll_tx_running(net))
return netvsc_vf_xmit(net, vf_netdev, skb);
/* We will atmost need two pages to describe the rndis