authorSebastian Reichel <sebastian.reichel@collabora.co.uk>2017-06-30 17:35:03 +0300
committerLee Jones <lee.jones@linaro.org>2017-09-05 10:46:00 +0300
commit45f80a9f78f1bcf87c09ae120a68011efe35128a (patch)
tree06618ac8184f9bf79dfa9abfea6999396ee837a1 /drivers/mfd/da9052-core.c
parente26ae3660b9ca2d180131670ae5388580dcf19b3 (diff)
downloadlinux-45f80a9f78f1bcf87c09ae120a68011efe35128a.tar.xz
mfd: da9052: Fix manual ADC read after timed out read
It is possible that under heavy system load, the counter in the completion struct, used for waiting for end of AD conversion, gets incremented twice. To make sure the driver recovers from this situation, the completion struct should be reinitialized. Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk> Signed-off-by: Lee Jones <lee.jones@linaro.org>
Diffstat (limited to 'drivers/mfd/da9052-core.c')
-rw-r--r--drivers/mfd/da9052-core.c2
1 files changed, 2 insertions, 0 deletions
diff --git a/drivers/mfd/da9052-core.c b/drivers/mfd/da9052-core.c
index a23a3a1c7061..433add43a0a9 100644
--- a/drivers/mfd/da9052-core.c
+++ b/drivers/mfd/da9052-core.c
@@ -387,6 +387,8 @@ int da9052_adc_manual_read(struct da9052 *da9052, unsigned char channel)
mutex_lock(&da9052->auxadc_lock);
+ reinit_completion(&da9052->done);
+
/* Channel gets activated on enabling the Conversion bit */
mux_sel = chan_mux[channel] | DA9052_ADC_MAN_MAN_CONV;