thermal: cpu_cooling: use cpufreq_policy to register cooling device
The CPU cooling driver uses the cpufreq policy, to get clip_cpus, the
frequency table, etc. Most of the callers of CPU cooling driver's
registration routines have the cpufreq policy with them, but they only
pass the policy->related_cpus cpumask. The __cpufreq_cooling_register()
routine then gets the policy by itself and uses it.
It would be much better if the callers can pass the policy instead
directly. This also fixes a basic design flaw, where the policy can be
freed while the CPU cooling driver is still active.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Diffstat (limited to 'drivers/cpufreq')
-rw-r--r-- | drivers/cpufreq/arm_big_little.c | 2 | ||||
-rw-r--r-- | drivers/cpufreq/cpufreq-dt.c | 2 | ||||
-rw-r--r-- | drivers/cpufreq/dbx500-cpufreq.c | 2 | ||||
-rw-r--r-- | drivers/cpufreq/mt8173-cpufreq.c | 4 | ||||
-rw-r--r-- | drivers/cpufreq/qoriq-cpufreq.c | 3 |
5 files changed, 5 insertions, 8 deletions
diff --git a/drivers/cpufreq/arm_big_little.c b/drivers/cpufreq/arm_big_little.c index 418042201e6d..ea6d62547b10 100644 --- a/drivers/cpufreq/arm_big_little.c +++ b/drivers/cpufreq/arm_big_little.c @@ -540,7 +540,7 @@ static void bL_cpufreq_ready(struct cpufreq_policy *policy) &power_coefficient); cdev[cur_cluster] = of_cpufreq_power_cooling_register(np, - policy->related_cpus, power_coefficient, NULL); + policy, power_coefficient, NULL); if (IS_ERR(cdev[cur_cluster])) { dev_err(cpu_dev, "running cpufreq without cooling device: %ld\n", diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c index c943787d761e..fef3c2160691 100644 --- a/drivers/cpufreq/cpufreq-dt.c +++ b/drivers/cpufreq/cpufreq-dt.c @@ -326,7 +326,7 @@ static void cpufreq_ready(struct cpufreq_policy *policy) &power_coefficient); priv->cdev = of_cpufreq_power_cooling_register(np, - policy->related_cpus, power_coefficient, NULL); + policy, power_coefficient, NULL); if (IS_ERR(priv->cdev)) { dev_err(priv->cpu_dev, "running cpufreq without cooling device: %ld\n", diff --git a/drivers/cpufreq/dbx500-cpufreq.c b/drivers/cpufreq/dbx500-cpufreq.c index 3575b82210ba..4ee0431579c1 100644 --- a/drivers/cpufreq/dbx500-cpufreq.c +++ b/drivers/cpufreq/dbx500-cpufreq.c @@ -43,7 +43,7 @@ static int dbx500_cpufreq_exit(struct cpufreq_policy *policy) static void dbx500_cpufreq_ready(struct cpufreq_policy *policy) { - cdev = cpufreq_cooling_register(policy->cpus); + cdev = cpufreq_cooling_register(policy); if (IS_ERR(cdev)) pr_err("Failed to register cooling device %ld\n", PTR_ERR(cdev)); else diff --git a/drivers/cpufreq/mt8173-cpufreq.c b/drivers/cpufreq/mt8173-cpufreq.c index fd1886faf33a..f9f00fb4bc3a 100644 --- a/drivers/cpufreq/mt8173-cpufreq.c +++ b/drivers/cpufreq/mt8173-cpufreq.c @@ -320,9 +320,7 @@ static void mtk_cpufreq_ready(struct cpufreq_policy *policy) of_property_read_u32(np, DYNAMIC_POWER, &capacitance); info->cdev = of_cpufreq_power_cooling_register(np, - policy->related_cpus, - capacitance, - NULL); + policy, capacitance, NULL); if (IS_ERR(info->cdev)) { dev_err(info->cpu_dev, diff --git a/drivers/cpufreq/qoriq-cpufreq.c b/drivers/cpufreq/qoriq-cpufreq.c index e2ea433a5f9c..4ada55b8856e 100644 --- a/drivers/cpufreq/qoriq-cpufreq.c +++ b/drivers/cpufreq/qoriq-cpufreq.c @@ -278,8 +278,7 @@ static void qoriq_cpufreq_ready(struct cpufreq_policy *policy) struct device_node *np = of_get_cpu_node(policy->cpu, NULL); if (of_find_property(np, "#cooling-cells", NULL)) { - cpud->cdev = of_cpufreq_cooling_register(np, - policy->related_cpus); + cpud->cdev = of_cpufreq_cooling_register(np, policy); if (IS_ERR(cpud->cdev) && PTR_ERR(cpud->cdev) != -ENOSYS) { pr_err("cpu%d is not running as cooling device: %ld\n", |