summaryrefslogtreecommitdiff
path: root/drivers/ata
diff options
context:
space:
mode:
authorOlof Johansson <olof@lixom.net>2007-01-19 03:39:59 +0300
committerJeff Garzik <jeff@garzik.org>2007-01-20 03:24:36 +0300
commite93f09dc2d49d8e98818a93ad17f3ede91533738 (patch)
tree43385c5b9a7f3852fa2773bb73edf71d8fcf34a9 /drivers/ata
parent79a55b72a1996f77e9d23c7a5282e5839d45beb3 (diff)
downloadlinux-e93f09dc2d49d8e98818a93ad17f3ede91533738.tar.xz
sata_mv HighPoint 2310 support (88SX7042)
With the following patch, my HighPoint 2310 with a Marvell 88SX7042 on it seems to work OK. The controller only has 4 ports, with MV_FLAG_DUAL_HC it seems to init 8 ports and fails miserably at probe time. There are no other devices mapped to that chip, maybe it was just incorrectly specified in the first place? Signed-off-by: Olof Johansson <olof@lixom.net> Signed-off-by: Jeff Garzik <jeff@garzik.org>
Diffstat (limited to 'drivers/ata')
-rw-r--r--drivers/ata/sata_mv.c5
1 files changed, 3 insertions, 2 deletions
diff --git a/drivers/ata/sata_mv.c b/drivers/ata/sata_mv.c
index 1b8e0eb9e032..aae0b5201c1e 100644
--- a/drivers/ata/sata_mv.c
+++ b/drivers/ata/sata_mv.c
@@ -523,8 +523,7 @@ static const struct ata_port_info mv_port_info[] = {
},
{ /* chip_7042 */
.sht = &mv_sht,
- .flags = (MV_COMMON_FLAGS | MV_6XXX_FLAGS |
- MV_FLAG_DUAL_HC),
+ .flags = (MV_COMMON_FLAGS | MV_6XXX_FLAGS),
.pio_mask = 0x1f, /* pio0-4 */
.udma_mask = 0x7f, /* udma0-6 */
.port_ops = &mv_iie_ops,
@@ -545,6 +544,8 @@ static const struct pci_device_id mv_pci_tbl[] = {
{ PCI_VDEVICE(ADAPTEC2, 0x0241), chip_604x },
+ { PCI_VDEVICE(TTI, 0x2310), chip_7042 },
+
{ } /* terminate list */
};