diff options
author | Yinghai Lu <Yinghai.Lu@Sun.COM> | 2008-02-29 10:56:50 +0300 |
---|---|---|
committer | Ingo Molnar <mingo@elte.hu> | 2008-04-27 01:41:04 +0400 |
commit | bb63b4219976d48ed6d22ac33c18be334fb5a78c (patch) | |
tree | fd63e9c86b43f246a1f7011881540718118890c9 /arch/x86/pci/direct.c | |
parent | d2ebdf4bae4f1d7c30e71fd74f270ca4cda024fc (diff) | |
download | linux-bb63b4219976d48ed6d22ac33c18be334fb5a78c.tar.xz |
x86 pci: remove checking type for mmconfig probe
doesn't need to check if it is type1 or type2, we can use raw_pci_ops
directly.
also make pci_direct_conf1 static again.
anyway is there system with type 2 and mmconf support?
Signed-off-by: Yinghai Lu <yinghai.lu@sun.com>
Signed-off-by: Ingo Molnar <mingo@elte.hu>
Diffstat (limited to 'arch/x86/pci/direct.c')
-rw-r--r-- | arch/x86/pci/direct.c | 8 |
1 files changed, 5 insertions, 3 deletions
diff --git a/arch/x86/pci/direct.c b/arch/x86/pci/direct.c index 42f3e4cad179..21d1e0e0d535 100644 --- a/arch/x86/pci/direct.c +++ b/arch/x86/pci/direct.c @@ -258,7 +258,8 @@ void __init pci_direct_init(int type) { if (type == 0) return; - printk(KERN_INFO "PCI: Using configuration type %d\n", type); + printk(KERN_INFO "PCI: Using configuration type %d for base access\n", + type); if (type == 1) raw_pci_ops = &pci_direct_conf1; else @@ -275,8 +276,10 @@ int __init pci_direct_probe(void) if (!region) goto type2; - if (pci_check_type1()) + if (pci_check_type1()) { + raw_pci_ops = &pci_direct_conf1; return 1; + } release_resource(region); type2: @@ -290,7 +293,6 @@ int __init pci_direct_probe(void) goto fail2; if (pci_check_type2()) { - printk(KERN_INFO "PCI: Using configuration type 2\n"); raw_pci_ops = &pci_direct_conf2; return 2; } |