ARM: tegra: nexus7: Improve thermal zones
Remove unused thermal zone just to clean up device-tree and set critical temperature further apart from the passive cooling trip point since during or thermal testing of Asus Transformer devices we found that CPU could reach the critical temperature in a certain kernel configurations for a brief moment if critical trip point is set close to the passive trip point and then device will be immediately shut off without getting a chance to cool down using passive cooling. Signed-off-by: Dmitry Osipenko <digetx@gmail.com> Signed-off-by: Thierry Reding <treding@nvidia.com>
Diffstat (limited to 'arch/arm/boot/dts/tegra30-asus-nexus7-grouper-common.dtsi')
-rw-r--r--arch/arm/boot/dts/tegra30-asus-nexus7-grouper-common.dtsi11
1 files changed, 2 insertions, 9 deletions
diff --git a/arch/arm/boot/dts/tegra30-asus-nexus7-grouper-common.dtsi b/arch/arm/boot/dts/tegra30-asus-nexus7-grouper-common.dtsi
index dc773b1bf8ee..3376d06facbb 100644
--- a/arch/arm/boot/dts/tegra30-asus-nexus7-grouper-common.dtsi
+++ b/arch/arm/boot/dts/tegra30-asus-nexus7-grouper-common.dtsi
@@ -1252,13 +1252,6 @@
};
thermal-zones {
- skin-thermal {
- polling-delay-passive = <1000>; /* milliseconds */
- polling-delay = <0>; /* milliseconds */
-
- thermal-sensors = <&nct72 0>;
- };
-
cpu-thermal {
polling-delay-passive = <1000>; /* milliseconds */
polling-delay = <5000>; /* milliseconds */
@@ -1274,8 +1267,8 @@
};
trip1: cpu-crit {
- /* shut down at 60C */
- temperature = <60000>;
+ /* shut down at 65C */
+ temperature = <65000>;
hysteresis = <2000>;
type = "critical";
};