diff options
author | Vineet Gupta <vgupta@synopsys.com> | 2013-05-09 12:15:12 +0400 |
---|---|---|
committer | Vineet Gupta <vgupta@synopsys.com> | 2013-05-09 12:15:12 +0400 |
commit | c917a36f5fe551748eb37bd1efdcccc1045a02ab (patch) | |
tree | 4204be45b5ae50eb412967080121664fe0ac4256 /arch/arc | |
parent | eacd0e950dc2100af54f2a94ae29105bf48ab921 (diff) | |
download | linux-c917a36f5fe551748eb37bd1efdcccc1045a02ab.tar.xz |
ARC: [mm] serious bug in vaddr based icache flush
vaddr used to index the cache was clipped from the wrong end, and thus
would potentially fail to flush the correct lines.
The problem was dorment for so long because up until the recent
optimizations it was only used for ptrace break-point only flushes.
Signed-off-by: Vineet Gupta <vgupta@synopsys.com>
Diffstat (limited to 'arch/arc')
-rw-r--r-- | arch/arc/mm/cache_arc700.c | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/arch/arc/mm/cache_arc700.c b/arch/arc/mm/cache_arc700.c index c854cf95f706..d48afebf9df5 100644 --- a/arch/arc/mm/cache_arc700.c +++ b/arch/arc/mm/cache_arc700.c @@ -421,7 +421,7 @@ static void __ic_line_inv_vaddr(unsigned long phy_start, unsigned long vaddr, num_lines = DIV_ROUND_UP(sz, ARC_ICACHE_LINE_LEN); #if (CONFIG_ARC_MMU_VER > 2) - vaddr &= ~ICACHE_LINE_MASK; + vaddr &= ICACHE_LINE_MASK; addr = phy_start; #else /* bits 17:13 of vaddr go as bits 4:0 of paddr */ |