diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2012-08-01 05:08:25 +0400 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2012-08-01 05:08:25 +0400 |
commit | 4b24ff71108164e047cf2c95990b77651163e315 (patch) | |
tree | 4b478906379adf22ff259fc1f2cce0da796df415 /Documentation | |
parent | bca1a5c0eabe0f17081760c61e8d08e73dd6b6a6 (diff) | |
parent | 4b1bf5871f7d59de6484cc887e205d6d2f1e6fbd (diff) | |
download | linux-4b24ff71108164e047cf2c95990b77651163e315.tar.xz |
Merge tag 'for-v3.6' of git://git.infradead.org/battery-2.6
Pull battery updates from Anton Vorontsov:
"The tag contains just a few battery-related changes for v3.6. It's is
all pretty straightforward, except one thing.
One of our patches added thermal support for power supply class, but
thermal/ subsystem changed under our feet. We (well, Stephen, that
is) caught the issue and it was decided[1] that I'd just delay the
battery pull request, and then will fix it up by merging upstream back
into battery tree at the specific commit.
That's not all though: another[2] small fixup for thermal subsystem
was needed to get rid of a warning in power supply subsystem (the
warning was not drivers/power's "fault", the thermal registration
function just needed a proper const annotation, which is also done by
a small commit on top of the merge.
So, to sum this up:
- The 'master' branch of the battery tree was in the -next tree for
weeks, was never rebased, altered etc. It should be all OK;
- Although, for-v3.6 tag contains the 'master' branch + merge + the
warning fix.
[1] http://lkml.org/lkml/2012/6/19/23
[2] http://lkml.org/lkml/2012/6/18/28"
* tag 'for-v3.6' of git://git.infradead.org/battery-2.6: (23 commits)
thermal: Constify 'type' argument for the registration routine
olpc-battery: update CHARGE_FULL_DESIGN property for BYD LiFe batteries
olpc-battery: Add VOLTAGE_MAX_DESIGN property
charger-manager: Fix build break related to EXTCON
lp8727_charger: Move header file into platform_data directory
power_supply: Add min/max alert properties for CAPACITY, TEMP, TEMP_AMBIENT
bq27x00_battery: Add support for BQ27425 chip
charger-manager: Set current limit of regulator for over current protection
charger-manager: Use EXTCON Subsystem to detect charger cables for charging
test_power: Add VOLTAGE_NOW and BATTERY_TEMP properties
test_power: Add support for USB AC source
gpio-charger: Use cansleep version of gpio_set_value
bq27x00_battery: Add support for power average and health properties
sbs-battery: Don't trigger false supply_changed event
twl4030_charger: Allow charger to control the regulator that feeds it
twl4030_charger: Add backup-battery charging
twl4030_charger: Fix some typos
max17042_battery: Support CHARGE_COUNTER power supply attribute
smb347-charger: Add constant charge and current properties
power_supply: Add constant charge_current and charge_voltage properties
...
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/power/power_supply_class.txt | 10 |
1 files changed, 10 insertions, 0 deletions
diff --git a/Documentation/power/power_supply_class.txt b/Documentation/power/power_supply_class.txt index 211831d4095f..2f0ddc15b5ac 100644 --- a/Documentation/power/power_supply_class.txt +++ b/Documentation/power/power_supply_class.txt @@ -112,14 +112,24 @@ CHARGE_COUNTER - the current charge counter (in µAh). This could easily be negative; there is no empty or full value. It is only useful for relative, time-based measurements. +CONSTANT_CHARGE_CURRENT - constant charge current programmed by charger. + +CONSTANT_CHARGE_VOLTAGE - constant charge voltage programmed by charger. + ENERGY_FULL, ENERGY_EMPTY - same as above but for energy. CAPACITY - capacity in percents. +CAPACITY_ALERT_MIN - minimum capacity alert value in percents. +CAPACITY_ALERT_MAX - maximum capacity alert value in percents. CAPACITY_LEVEL - capacity level. This corresponds to POWER_SUPPLY_CAPACITY_LEVEL_*. TEMP - temperature of the power supply. +TEMP_ALERT_MIN - minimum battery temperature alert value in milli centigrade. +TEMP_ALERT_MAX - maximum battery temperature alert value in milli centigrade. TEMP_AMBIENT - ambient temperature. +TEMP_AMBIENT_ALERT_MIN - minimum ambient temperature alert value in milli centigrade. +TEMP_AMBIENT_ALERT_MAX - maximum ambient temperature alert value in milli centigrade. TIME_TO_EMPTY - seconds left for battery to be considered empty (i.e. while battery powers a load) |