diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2018-08-24 23:03:51 +0300 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2018-08-24 23:03:51 +0300 |
commit | d972604f6f87478212f012af5560c4fd4bb2b01d (patch) | |
tree | 47f043843ccbf0ee609aeb13267a76ed9c26f9fd /Documentation | |
parent | 57bb8e37d71eac45b6ea9180698a9cc3db945e26 (diff) | |
parent | d7a4303b8d1fa6f60b73ed91317a51764a2a412c (diff) | |
download | linux-d972604f6f87478212f012af5560c4fd4bb2b01d.tar.xz |
Merge branch 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal management updates from Zhang Rui:
- Add Daniel Lezcano as the reviewer of thermal framework and SoC
driver changes (Daniel Lezcano).
- Fix a bug in intel_dts_soc_thermal driver, which does not translate
IO-APIC GSI (Global System Interrupt) into Linux irq number (Hans de
Goede).
- For device tree bindings, allow cooling devices sharing same trip
point with same contribution value to share cooling map (Viresh
Kumar).
* 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux:
dt-bindings: thermal: Allow multiple devices to share cooling map
MAINTAINERS: Add Daniel Lezcano as designated reviewer for thermal
Thermal: Intel SoC DTS: Translate IO-APIC GSI number to linux irq number
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/devicetree/bindings/thermal/thermal.txt | 11 |
1 files changed, 3 insertions, 8 deletions
diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt index cc553f0952c5..eb7ee91556a5 100644 --- a/Documentation/devicetree/bindings/thermal/thermal.txt +++ b/Documentation/devicetree/bindings/thermal/thermal.txt @@ -97,8 +97,8 @@ get assigned to trip points of the zone. The cooling devices are expected to be loaded in the target system. Required properties: -- cooling-device: A phandle of a cooling device with its specifier, - Type: phandle + referring to which cooling device is used in this +- cooling-device: A list of phandles of cooling devices with their specifiers, + Type: phandle + referring to which cooling devices are used in this cooling specifier binding. In the cooling specifier, the first cell is the minimum cooling state and the second cell is the maximum cooling state used in this map. @@ -276,12 +276,7 @@ thermal-zones { }; map1 { trip = <&cpu_alert1>; - cooling-device = <&fan0 5 THERMAL_NO_LIMIT>; - }; - map2 { - trip = <&cpu_alert1>; - cooling-device = - <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; + cooling-device = <&fan0 5 THERMAL_NO_LIMIT>, <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; }; }; }; |