x86, hwmon: Package Level Thermal/Power: pkgtemp documentation
Document for package level thermal hwmon driver. Signed-off-by: Fenghua Yu <fenghua.yu@intel.com> LKML-Reference: <1280448826-12004-6-git-send-email-fenghua.yu@intel.com> Reviewed-by: Len Brown <len.brown@intel.com> Signed-off-by: H. Peter Anvin <hpa@linux.intel.com>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/hwmon/pkgtemp36
1 files changed, 36 insertions, 0 deletions
diff --git a/Documentation/hwmon/pkgtemp b/Documentation/hwmon/pkgtemp
new file mode 100644
index 000000000000..c8e1fb0fadd3
--- /dev/null
+++ b/Documentation/hwmon/pkgtemp
@@ -0,0 +1,36 @@
+Kernel driver pkgtemp
+======================
+
+Supported chips:
+ * Intel family
+ Prefix: 'pkgtemp'
+ CPUID:
+ Datasheet: Intel 64 and IA-32 Architectures Software Developer's Manual
+ Volume 3A: System Programming Guide
+
+Author: Fenghua Yu
+
+Description
+-----------
+
+This driver permits reading package level temperature sensor embedded inside
+Intel CPU package. The sensors can be in core, uncore, memory controller, or
+other components in a package. The feature is first implemented in Intel Sandy
+Bridge platform.
+
+Temperature is measured in degrees Celsius and measurement resolution is
+1 degree C. Valid temperatures are from 0 to TjMax degrees C, because the actual
+value of temperature register is in fact a delta from TjMax.
+
+Temperature known as TjMax is the maximum junction temperature of package.
+We get this from MSR_IA32_TEMPERATURE_TARGET. If the MSR is not accessible,
+we define TjMax as 100 degrees Celsius. At this temperature, protection
+mechanism will perform actions to forcibly cool down the package. Alarm
+may be raised, if the temperature grows enough (more than TjMax) to trigger
+the Out-Of-Spec bit. Following table summarizes the exported sysfs files:
+
+temp1_input - Package temperature (in millidegrees Celsius).
+temp1_max - All cooling devices should be turned on.
+temp1_crit - Maximum junction temperature (in millidegrees Celsius).
+temp1_crit_alarm - Set when Out-of-spec bit is set, never clears.
+ Correct CPU operation is no longer guaranteed.