Merge branch 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal management updates from Zhang Rui: - Fix a problem where orderly_shutdown() is called for multiple times due to multiple critical overheating events raised in a short period by platform thermal driver. (Keerthy) - Introduce a backup thermal shutdown mechanism, which invokes kernel_power_off()/emergency_restart() directly, after orderly_shutdown() being issued for certain amount of time(specified via Kconfig). This is useful in certain conditions that userspace may be unable to power off the system in a clean manner and leaves the system in a critical state, like in the middle of driver probing phase. (Keerthy) - Introduce a new interface in thermal devfreq_cooling code so that the driver can provide more precise data regarding actual power to the thermal governor every time the power budget is calculated. (Lukasz Luba) - Introduce BCM 2835 soc thermal driver and northstar thermal driver, within a new sub-folder. (Rafał Miłecki) - Introduce DA9062/61 thermal driver. (Steve Twiss) - Remove non-DT booting on TI-SoC driver. Also add support to fetching coefficients from DT. (Keerthy) - Refactorf RCAR Gen3 thermal driver. (Niklas Söderlund) - Small fix on MTK and intel-soc-dts thermal driver. (Dawei Chien, Brian Bian) * 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: (25 commits) thermal: core: Add a back up thermal shutdown mechanism thermal: core: Allow orderly_poweroff to be called only once Thermal: Intel SoC DTS: Change interrupt request behavior trace: thermal: add another parameter 'power' to the tracing function thermal: devfreq_cooling: add new interface for direct power read thermal: devfreq_cooling: refactor code and add get_voltage function thermal: mt8173: minor mtk_thermal.c cleanups thermal: bcm2835: move to the broadcom subdirectory thermal: broadcom: ns: specify myself as MODULE_AUTHOR thermal: da9062/61: Thermal junction temperature monitoring driver Documentation: devicetree: thermal: da9062/61 TJUNC temperature binding thermal: broadcom: add Northstar thermal driver dt-bindings: thermal: add support for Broadcom's Northstar thermal thermal: bcm2835: add thermal driver for bcm2835 SoC dt-bindings: Add thermal zone to bcm2835-thermal example thermal: rcar_gen3_thermal: add suspend and resume support thermal: rcar_gen3_thermal: store device match data in private structure thermal: rcar_gen3_thermal: enable hardware interrupts for trip points thermal: rcar_gen3_thermal: record and check number of TSCs found thermal: rcar_gen3_thermal: check that TSC exists before memory allocation ...
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/devicetree/bindings/thermal/brcm,bcm2835-thermal.txt32
-rw-r--r--Documentation/devicetree/bindings/thermal/brcm,ns-thermal37
-rw-r--r--Documentation/devicetree/bindings/thermal/da9062-thermal.txt36
-rw-r--r--Documentation/thermal/sysfs-api.txt21
4 files changed, 122 insertions, 4 deletions
diff --git a/Documentation/devicetree/bindings/thermal/brcm,bcm2835-thermal.txt b/Documentation/devicetree/bindings/thermal/brcm,bcm2835-thermal.txt
index 474531d2b2c5..da8c5b73ad10 100644
--- a/Documentation/devicetree/bindings/thermal/brcm,bcm2835-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/brcm,bcm2835-thermal.txt
@@ -3,15 +3,39 @@ Binding for Thermal Sensor driver for BCM2835 SoCs.
Required parameters:
-------------------
-compatible: should be one of: "brcm,bcm2835-thermal",
- "brcm,bcm2836-thermal" or "brcm,bcm2837-thermal"
-reg: Address range of the thermal registers.
-clocks: Phandle of the clock used by the thermal sensor.
+compatible: should be one of: "brcm,bcm2835-thermal",
+ "brcm,bcm2836-thermal" or "brcm,bcm2837-thermal"
+reg: Address range of the thermal registers.
+clocks: Phandle of the clock used by the thermal sensor.
+#thermal-sensor-cells: should be 0 (see thermal.txt)
Example:
+thermal-zones {
+ cpu_thermal: cpu-thermal {
+ polling-delay-passive = <0>;
+ polling-delay = <1000>;
+
+ thermal-sensors = <&thermal>;
+
+ trips {
+ cpu-crit {
+ temperature = <80000>;
+ hysteresis = <0>;
+ type = "critical";
+ };
+ };
+
+ coefficients = <(-538) 407000>;
+
+ cooling-maps {
+ };
+ };
+};
+
thermal: thermal@7e212000 {
compatible = "brcm,bcm2835-thermal";
reg = <0x7e212000 0x8>;
clocks = <&clocks BCM2835_CLOCK_TSENS>;
+ #thermal-sensor-cells = <0>;
};
diff --git a/Documentation/devicetree/bindings/thermal/brcm,ns-thermal b/Documentation/devicetree/bindings/thermal/brcm,ns-thermal
new file mode 100644
index 000000000000..68e047170039
--- /dev/null
+++ b/Documentation/devicetree/bindings/thermal/brcm,ns-thermal
@@ -0,0 +1,37 @@
+* Broadcom Northstar Thermal
+
+This binding describes thermal sensor that is part of Northstar's DMU (Device
+Management Unit).
+
+Required properties:
+- compatible : Must be "brcm,ns-thermal"
+- reg : iomem address range of PVTMON registers
+- #thermal-sensor-cells : Should be <0>
+
+Example:
+
+thermal: thermal@1800c2c0 {
+ compatible = "brcm,ns-thermal";
+ reg = <0x1800c2c0 0x10>;
+ #thermal-sensor-cells = <0>;
+};
+
+thermal-zones {
+ cpu_thermal: cpu-thermal {
+ polling-delay-passive = <0>;
+ polling-delay = <1000>;
+ coefficients = <(-556) 418000>;
+ thermal-sensors = <&thermal>;
+
+ trips {
+ cpu-crit {
+ temperature = <125000>;
+ hysteresis = <0>;
+ type = "critical";
+ };
+ };
+
+ cooling-maps {
+ };
+ };
+};
diff --git a/Documentation/devicetree/bindings/thermal/da9062-thermal.txt b/Documentation/devicetree/bindings/thermal/da9062-thermal.txt
new file mode 100644
index 000000000000..e241bb5a5584
--- /dev/null
+++ b/Documentation/devicetree/bindings/thermal/da9062-thermal.txt
@@ -0,0 +1,36 @@
+* Dialog DA9062/61 TJUNC Thermal Module
+
+This module is part of the DA9061/DA9062. For more details about entire
+DA9062 and DA9061 chips see Documentation/devicetree/bindings/mfd/da9062.txt
+
+Junction temperature thermal module uses an interrupt signal to identify
+high THERMAL_TRIP_HOT temperatures for the PMIC device.
+
+Required properties:
+
+- compatible: should be one of the following valid compatible string lines:
+ "dlg,da9061-thermal", "dlg,da9062-thermal"
+ "dlg,da9062-thermal"
+
+Optional properties:
+
+- polling-delay-passive : Specify the polling period, measured in
+ milliseconds, between thermal zone device update checks.
+
+Example: DA9062
+
+ pmic0: da9062@58 {
+ thermal {
+ compatible = "dlg,da9062-thermal";
+ polling-delay-passive = <3000>;
+ };
+ };
+
+Example: DA9061 using a fall-back compatible for the DA9062 onkey driver
+
+ pmic0: da9061@58 {
+ thermal {
+ compatible = "dlg,da9061-thermal", "dlg,da9062-thermal";
+ polling-delay-passive = <3000>;
+ };
+ };
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt
index ef473dc7f55e..bb9a0a53e76b 100644
--- a/Documentation/thermal/sysfs-api.txt
+++ b/Documentation/thermal/sysfs-api.txt
@@ -582,3 +582,24 @@ platform data is provided, this uses the step_wise throttling policy.
This function serves as an arbitrator to set the state of a cooling
device. It sets the cooling device to the deepest cooling state if
possible.
+
+6. thermal_emergency_poweroff:
+
+On an event of critical trip temperature crossing. Thermal framework
+allows the system to shutdown gracefully by calling orderly_poweroff().
+In the event of a failure of orderly_poweroff() to shut down the system
+we are in danger of keeping the system alive at undesirably high
+temperatures. To mitigate this high risk scenario we program a work
+queue to fire after a pre-determined number of seconds to start
+an emergency shutdown of the device using the kernel_power_off()
+function. In case kernel_power_off() fails then finally
+emergency_restart() is called in the worst case.
+
+The delay should be carefully profiled so as to give adequate time for
+orderly_poweroff(). In case of failure of an orderly_poweroff() the
+emergency poweroff kicks in after the delay has elapsed and shuts down
+the system.
+
+If set to 0 emergency poweroff will not be supported. So a carefully
+profiled non-zero positive value is a must for emergerncy poweroff to be
+triggered.