summaryrefslogtreecommitdiff
path: root/Documentation/thermal
diff options
context:
space:
mode:
authorZhang Rui <rui.zhang@intel.com>2012-07-25 06:11:00 +0400
committerLen Brown <len.brown@intel.com>2012-07-25 07:20:40 +0400
commit8eaa8d6ca27788aa23659082362a608c1fabcdfe (patch)
treec6df5382dd740a98e29676a96630a11d09d7ec47 /Documentation/thermal
parent27365a6c7d64a3bba22ee62109e4a071bbd7f933 (diff)
downloadlinux-8eaa8d6ca27788aa23659082362a608c1fabcdfe.tar.xz
Thermal: Documentation update
With commit 6503e5df08008b9a47022b5e9ebba658c8fa69af, the value of /sys/class/thermal/thermal_zoneX/mode has been changed from user/kernel to enabled/disabled. Update the documentation so that users won't be confused. Signed-off-by: Zhang Rui <rui.zhang@intel.com> Signed-off-by: Len Brown <len.brown@intel.com>
Diffstat (limited to 'Documentation/thermal')
-rw-r--r--Documentation/thermal/sysfs-api.txt20
1 files changed, 10 insertions, 10 deletions
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt
index 2ba4c9bb790a..c087dbcf3535 100644
--- a/Documentation/thermal/sysfs-api.txt
+++ b/Documentation/thermal/sysfs-api.txt
@@ -47,11 +47,11 @@ temperature) and throttle appropriate devices.
.bind: bind the thermal zone device with a thermal cooling device.
.unbind: unbind the thermal zone device with a thermal cooling device.
.get_temp: get the current temperature of the thermal zone.
- .get_mode: get the current mode (user/kernel) of the thermal zone.
- - "kernel" means thermal management is done in kernel.
- - "user" will prevent kernel thermal driver actions upon trip points
+ .get_mode: get the current mode (enabled/disabled) of the thermal zone.
+ - "enabled" means the kernel thermal management is enabled.
+ - "disabled" will prevent kernel thermal driver action upon trip points
so that user applications can take charge of thermal management.
- .set_mode: set the mode (user/kernel) of the thermal zone.
+ .set_mode: set the mode (enabled/disabled) of the thermal zone.
.get_trip_type: get the type of certain trip point.
.get_trip_temp: get the temperature above which the certain trip point
will be fired.
@@ -170,14 +170,14 @@ temp
RO, Required
mode
- One of the predefined values in [kernel, user].
+ One of the predefined values in [enabled, disabled].
This file gives information about the algorithm that is currently
managing the thermal zone. It can be either default kernel based
algorithm or user space application.
- kernel = Thermal management in kernel thermal zone driver.
- user = Preventing kernel thermal zone driver actions upon
- trip points so that user application can take full
- charge of the thermal management.
+ enabled = enable Kernel Thermal management.
+ disabled = Preventing kernel thermal zone driver actions upon
+ trip points so that user application can take full
+ charge of the thermal management.
RW, Optional
trip_point_[0-*]_temp
@@ -256,7 +256,7 @@ method, the sys I/F structure will be built like this:
|thermal_zone1:
|---type: acpitz
|---temp: 37000
- |---mode: kernel
+ |---mode: enabled
|---trip_point_0_temp: 100000
|---trip_point_0_type: critical
|---trip_point_1_temp: 80000