authorGuenter Roeck <linux@roeck-us.net>2014-07-17 04:40:31 +0400
committerGuenter Roeck <linux@roeck-us.net>2014-07-17 08:18:47 +0400
commitde12d6f4b10b21854441f5242dcb29ea96181e58 (patch)
treebd197e8e568310bb71c6469f7d9242ed8b056df1 /Documentation/serial
parent6b00f440dd678d786389a7100a2e03fe44478431 (diff)
downloadlinux-de12d6f4b10b21854441f5242dcb29ea96181e58.tar.xz
hwmon: (adt7470) Fix writes to temperature limit registers
Temperature limit registers are signed. Limits therefore need to be clamped to (-128, 127) degrees C and not to (0, 255) degrees C. Without this fix, writing a limit of 128 degrees C sets the actual limit to -128 degrees C. Signed-off-by: Guenter Roeck <linux@roeck-us.net> Cc: stable@vger.kernel.org Reviewed-by: Axel Lin <axel.lin@ingics.com>