summaryrefslogtreecommitdiff
path: root/Documentation/hwmon
diff options
context:
space:
mode:
authorGuenter Roeck <linux@roeck-us.net>2024-07-01 18:57:58 +0300
committerGuenter Roeck <linux@roeck-us.net>2024-07-08 17:52:36 +0300
commit4814241a5817ce8140dda8f1375bf76f99e68697 (patch)
treea74618ab4f083bfed7be5b8ed8661a694d6b474c /Documentation/hwmon
parente98ab50e1f2dd6ab8d1bddae4f9857725defafbc (diff)
downloadlinux-4814241a5817ce8140dda8f1375bf76f99e68697.tar.xz
hwmon: (amc6821) Add support for pwm1_mode attribute
AMC6821 supports configuring if a fan is DC or PWM controlled. Add support for the pwm1_mode attribute to make it runtime configurable. Reviewed-by: Quentin Schulz <quentin.schulz@cherry.de> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/amc6821.rst1
1 files changed, 1 insertions, 0 deletions
diff --git a/Documentation/hwmon/amc6821.rst b/Documentation/hwmon/amc6821.rst
index 96e604c5ea8e..dbd544cd1160 100644
--- a/Documentation/hwmon/amc6821.rst
+++ b/Documentation/hwmon/amc6821.rst
@@ -58,6 +58,7 @@ pwm1_enable rw regulator mode, 1=open loop, 2=fan controlled
remote-sensor temperature,
4=fan controlled by target rpm set with
fan1_target attribute.
+pwm1_mode rw Fan duty control mode (0=DC, 1=PWM)
pwm1_auto_channels_temp ro 1 if pwm_enable==2, 3 if pwm_enable==3
pwm1_auto_point1_pwm ro Hardwired to 0, shared for both
temperature channels.