summaryrefslogtreecommitdiff
path: root/Documentation/hwmon/max16064
diff options
context:
space:
mode:
authorGuenter Roeck <guenter.roeck@ericsson.com>2011-07-10 00:10:19 +0400
committerGuenter Roeck <guenter.roeck@ericsson.com>2011-07-29 04:09:53 +0400
commit8ebed854506301f4f67e75c73cae967d4a45ab4d (patch)
tree931d27507b081f39551cc1092b5db6fd1812f9a0 /Documentation/hwmon/max16064
parentc576e30cd0c9814b3b45772d46924d796f538dee (diff)
downloadlinux-8ebed854506301f4f67e75c73cae967d4a45ab4d.tar.xz
hwmon: (max16064) Add support for peak attributes
Add support for voltage and temperature peak (historic maximum) attributes. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Diffstat (limited to 'Documentation/hwmon/max16064')
-rw-r--r--Documentation/hwmon/max160644
1 files changed, 4 insertions, 0 deletions
diff --git a/Documentation/hwmon/max16064 b/Documentation/hwmon/max16064
index 41728999e142..f6e8bcbfaccf 100644
--- a/Documentation/hwmon/max16064
+++ b/Documentation/hwmon/max16064
@@ -50,6 +50,8 @@ in[1-4]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
in[1-4]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
in[1-4]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
in[1-4]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
+in[1-4]_highest Historical maximum voltage.
+in[1-4]_reset_history Write any value to reset history.
temp1_input Measured temperature. From READ_TEMPERATURE_1 register.
temp1_max Maximum temperature. From OT_WARN_LIMIT register.
@@ -60,3 +62,5 @@ temp1_max_alarm Chip temperature high alarm. Set by comparing
temp1_crit_alarm Chip temperature critical high alarm. Set by comparing
READ_TEMPERATURE_1 with OT_FAULT_LIMIT if TEMP_OT_FAULT
status is set.
+temp1_highest Historical maximum temperature.
+temp1_reset_history Write any value to reset history.