summaryrefslogtreecommitdiff
path: root/Documentation/devicetree/bindings/pwm
diff options
context:
space:
mode:
authorYash Shah <yash.shah@sifive.com>2019-06-11 08:44:43 +0300
committerThierry Reding <thierry.reding@gmail.com>2019-06-25 15:47:28 +0300
commitdaa78cc3408e7145d99462d51c5f4c6b0cb2af9c (patch)
tree20c9a2b602631fc93742b016488daec6e8c8e2b7 /Documentation/devicetree/bindings/pwm
parenta188339ca5a396acc588e5851ed7e19f66b0ebd9 (diff)
downloadlinux-daa78cc3408e7145d99462d51c5f4c6b0cb2af9c.tar.xz
pwm: sifive: Add DT documentation for SiFive PWM Controller
DT documentation for PWM controller added. Signed-off-by: Wesley W. Terpstra <wesley@sifive.com> [Atish: Compatible string update] Signed-off-by: Atish Patra <atish.patra@wdc.com> Signed-off-by: Yash Shah <yash.shah@sifive.com> Reviewed-by: Rob Herring <robh@kernel.org> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
Diffstat (limited to 'Documentation/devicetree/bindings/pwm')
-rw-r--r--Documentation/devicetree/bindings/pwm/pwm-sifive.txt33
1 files changed, 33 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/pwm/pwm-sifive.txt b/Documentation/devicetree/bindings/pwm/pwm-sifive.txt
new file mode 100644
index 000000000000..36447e3c9378
--- /dev/null
+++ b/Documentation/devicetree/bindings/pwm/pwm-sifive.txt
@@ -0,0 +1,33 @@
+SiFive PWM controller
+
+Unlike most other PWM controllers, the SiFive PWM controller currently only
+supports one period for all channels in the PWM. All PWMs need to run at
+the same period. The period also has significant restrictions on the values
+it can achieve, which the driver rounds to the nearest achievable period.
+PWM RTL that corresponds to the IP block version numbers can be found
+here:
+
+https://github.com/sifive/sifive-blocks/tree/master/src/main/scala/devices/pwm
+
+Required properties:
+- compatible: Should be "sifive,<chip>-pwm" and "sifive,pwm<version>".
+ Supported compatible strings are: "sifive,fu540-c000-pwm" for the SiFive
+ PWM v0 as integrated onto the SiFive FU540 chip, and "sifive,pwm0" for the
+ SiFive PWM v0 IP block with no chip integration tweaks.
+ Please refer to sifive-blocks-ip-versioning.txt for details.
+- reg: physical base address and length of the controller's registers
+- clocks: Should contain a clock identifier for the PWM's parent clock.
+- #pwm-cells: Should be 3. See pwm.txt in this directory
+ for a description of the cell format.
+- interrupts: one interrupt per PWM channel
+
+Examples:
+
+pwm: pwm@10020000 {
+ compatible = "sifive,fu540-c000-pwm", "sifive,pwm0";
+ reg = <0x0 0x10020000 0x0 0x1000>;
+ clocks = <&tlclk>;
+ interrupt-parent = <&plic>;
+ interrupts = <42 43 44 45>;
+ #pwm-cells = <3>;
+};