HID: hid-sensor-hub: fix report size
Most of the hid sensor field size is reported in report_size field in the report descriptor. For rotation fusion sensor the quaternion data is 16 byte field, the report size was set to 4 and report count field is set to 4. So the total size is 16 bytes. But the current driver has a bug and not taking account for report count field. This causes user space to see only 4 bytes of data sent via IIO interface. The number of bytes in a field needs to take account of report_count field. Need to multiply report_size and report_count to get total number of bytes. Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
-rw-r--r--drivers/hid/hid-sensor-hub.c13
1 files changed, 8 insertions, 5 deletions
diff --git a/drivers/hid/hid-sensor-hub.c b/drivers/hid/hid-sensor-hub.c
index 10e1581022cf..9e4cdca549c0 100644
--- a/drivers/hid/hid-sensor-hub.c
+++ b/drivers/hid/hid-sensor-hub.c
@@ -326,7 +326,8 @@ int sensor_hub_input_get_attribute_info(struct hid_sensor_hub_device *hsdev,
field->logical == attr_usage_id) {
sensor_hub_fill_attr_info(info, i, report->id,
field->unit, field->unit_exponent,
- field->report_size);
+ field->report_size *
+ field->report_count);
ret = 0;
} else {
for (j = 0; j < field->maxusage; ++j) {
@@ -338,7 +339,8 @@ int sensor_hub_input_get_attribute_info(struct hid_sensor_hub_device *hsdev,
i, report->id,
field->unit,
field->unit_exponent,
- field->report_size);
+ field->report_size *
+ field->report_count);
ret = 0;
break;
}
@@ -425,9 +427,10 @@ static int sensor_hub_raw_event(struct hid_device *hdev,
hid_dbg(hdev, "%d collection_index:%x hid:%x sz:%x\n",
i, report->field[i]->usage->collection_index,
report->field[i]->usage->hid,
- report->field[i]->report_size/8);
-
- sz = report->field[i]->report_size/8;
+ (report->field[i]->report_size *
+ report->field[i]->report_count)/8);
+ sz = (report->field[i]->report_size *
+ report->field[i]->report_count)/8;
if (pdata->pending.status && pdata->pending.attr_usage_id ==
report->field[i]->usage->hid) {
hid_dbg(hdev, "data was pending ...\n");