summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorAnson Huang <anson.huang@nxp.com>2018-11-21 08:49:36 +0300
committerEduardo Valentin <edubezval@gmail.com>2019-01-02 15:47:12 +0300
commitc589c56671c914fbd6b56a6f92dce80edbbfdada (patch)
tree2f49329b823a3b0551214d2e43a7e978802a957a
parent4ab248b3b10a58e379e2d32333fff99ea5ca256c (diff)
downloadlinux-c589c56671c914fbd6b56a6f92dce80edbbfdada.tar.xz
thermal: imx: fix for dependency on cpu-freq
The thermal driver is a standalone driver for monitoring SoC temperature by enabling thermal sensor, so it can be enabled even when CONFIG_CPU_FREQ is NOT set. So remove the dependency with CPU_THERMAL. Introduce dummy function of legacy cooling register/unregister to make thermal driver probe successfully when CONFIG_CPU_FREQ is NOT set. Signed-off-by: Anson Huang <Anson.Huang@nxp.com> Acked-by: Viresh Kumar <viresh.kumar@linaro.org> Reviewed-by: Daniel Lezcano <daniel.lezcano@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
-rw-r--r--drivers/thermal/Kconfig2
-rw-r--r--drivers/thermal/imx_thermal.c47
2 files changed, 36 insertions, 13 deletions
diff --git a/drivers/thermal/Kconfig b/drivers/thermal/Kconfig
index 5422523c03f8..93bd3bbefb9a 100644
--- a/drivers/thermal/Kconfig
+++ b/drivers/thermal/Kconfig
@@ -212,7 +212,7 @@ config HISI_THERMAL
config IMX_THERMAL
tristate "Temperature sensor driver for Freescale i.MX SoCs"
- depends on (ARCH_MXC && CPU_THERMAL) || COMPILE_TEST
+ depends on ARCH_MXC || COMPILE_TEST
depends on NVMEM || !NVMEM
depends on MFD_SYSCON
depends on OF
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
index 15661549eb67..c924396685a0 100644
--- a/drivers/thermal/imx_thermal.c
+++ b/drivers/thermal/imx_thermal.c
@@ -648,15 +648,24 @@ static const struct of_device_id of_imx_thermal_match[] = {
};
MODULE_DEVICE_TABLE(of, of_imx_thermal_match);
+#ifdef CONFIG_CPU_FREQ
/*
* Create cooling device in case no #cooling-cells property is available in
* CPU node
*/
static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
{
- struct device_node *np = of_get_cpu_node(data->policy->cpu, NULL);
+ struct device_node *np;
int ret;
+ data->policy = cpufreq_cpu_get(0);
+ if (!data->policy) {
+ pr_debug("%s: CPUFreq policy not found\n", __func__);
+ return -EPROBE_DEFER;
+ }
+
+ np = of_get_cpu_node(data->policy->cpu, NULL);
+
if (!np || !of_find_property(np, "#cooling-cells", NULL)) {
data->cdev = cpufreq_cooling_register(data->policy);
if (IS_ERR(data->cdev)) {
@@ -669,6 +678,24 @@ static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
return 0;
}
+static void imx_thermal_unregister_legacy_cooling(struct imx_thermal_data *data)
+{
+ cpufreq_cooling_unregister(data->cdev);
+ cpufreq_cpu_put(data->policy);
+}
+
+#else
+
+static inline int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
+{
+ return 0;
+}
+
+static inline void imx_thermal_unregister_legacy_cooling(struct imx_thermal_data *data)
+{
+}
+#endif
+
static int imx_thermal_probe(struct platform_device *pdev)
{
struct imx_thermal_data *data;
@@ -743,14 +770,11 @@ static int imx_thermal_probe(struct platform_device *pdev)
regmap_write(map, data->socdata->sensor_ctrl + REG_SET,
data->socdata->power_down_mask);
- data->policy = cpufreq_cpu_get(0);
- if (!data->policy) {
- pr_debug("%s: CPUFreq policy not found\n", __func__);
- return -EPROBE_DEFER;
- }
-
ret = imx_thermal_register_legacy_cooling(data);
if (ret) {
+ if (ret == -EPROBE_DEFER)
+ return ret;
+
dev_err(&pdev->dev,
"failed to register cpufreq cooling device: %d\n", ret);
return ret;
@@ -762,7 +786,7 @@ static int imx_thermal_probe(struct platform_device *pdev)
if (ret != -EPROBE_DEFER)
dev_err(&pdev->dev,
"failed to get thermal clk: %d\n", ret);
- goto cpufreq_put;
+ goto legacy_cleanup;
}
/*
@@ -775,7 +799,7 @@ static int imx_thermal_probe(struct platform_device *pdev)
ret = clk_prepare_enable(data->thermal_clk);
if (ret) {
dev_err(&pdev->dev, "failed to enable thermal clk: %d\n", ret);
- goto cpufreq_put;
+ goto legacy_cleanup;
}
data->tz = thermal_zone_device_register("imx_thermal_zone",
@@ -829,9 +853,8 @@ thermal_zone_unregister:
thermal_zone_device_unregister(data->tz);
clk_disable:
clk_disable_unprepare(data->thermal_clk);
-cpufreq_put:
- cpufreq_cooling_unregister(data->cdev);
- cpufreq_cpu_put(data->policy);
+legacy_cleanup:
+ imx_thermal_unregister_legacy_cooling(data);
return ret;
}