* Texas Instruments LMP91000 series of potentiostats
LMP91000: http://www.ti.com/lit/ds/symlink/lmp91000.pdf
LMP91002: http://www.ti.com/lit/ds/symlink/lmp91002.pdf
Required properties:
- compatible: should be one of the following:
"ti,lmp91000"
"ti,lmp91002"
- reg: the I2C address of the device
- io-channels: the phandle of the iio provider
- ti,external-tia-resistor: if the property ti,tia-gain-ohm is not defined this
needs to be set to signal that an external resistor value is being used.
Optional properties:
- ti,tia-gain-ohm: ohm value of the internal resistor for the transimpedance
amplifier. Must be 2750, 3500, 7000, 14000, 35000, 120000, or 350000 ohms.
- ti,rload-ohm: ohm value of the internal resistor load applied to the gas
sensor. Must be 10, 33, 50, or 100 (default) ohms.
Example:
lmp91000@48 {
compatible = "ti,lmp91000";
reg = <0x48>;
ti,tia-gain-ohm = <7500>;
ti,rload = <100>;
io-channels = <&adc>;
};
|