From f011539e723c737b74876ac47345e40270a3c384 Mon Sep 17 00:00:00 2001 From: Bongsu Jeon Date: Thu, 31 Dec 2020 11:59:26 +0900 Subject: net: nfc: nci: Change the NCI close sequence If there is a NCI command in work queue after closing the NCI device at nci_unregister_device, The NCI command timer starts at flush_workqueue function and then NCI command timeout handler would be called 5 second after flushing the NCI command work queue and destroying the queue. At that time, the timeout handler would try to use NCI command work queue that is destroyed already. it will causes the problem. To avoid this abnormal situation, change the sequence to prevent the NCI command timeout handler from being called after destroying the NCI command work queue. Signed-off-by: Bongsu Jeon Signed-off-by: David S. Miller --- net/nfc/nci/core.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) (limited to 'net/nfc/nci/core.c') diff --git a/net/nfc/nci/core.c b/net/nfc/nci/core.c index e64727e1a72f..79bebf4b0796 100644 --- a/net/nfc/nci/core.c +++ b/net/nfc/nci/core.c @@ -579,11 +579,11 @@ static int nci_close_device(struct nci_dev *ndev) clear_bit(NCI_INIT, &ndev->flags); - del_timer_sync(&ndev->cmd_timer); - /* Flush cmd wq */ flush_workqueue(ndev->cmd_wq); + del_timer_sync(&ndev->cmd_timer); + /* Clear flags */ ndev->flags = 0; -- cgit v1.2.3