From 5000806c119799715f315e482fb60cc61e2536ea Mon Sep 17 00:00:00 2001 From: Amit Daniel Kachhap Date: Mon, 24 Jun 2013 16:20:45 +0530 Subject: thermal: exynos: Fix to set the second point correction value This patch sets the second point trimming value according to the platform data if the register value is 0. Acked-by: Jonghwa Lee Acked-by: Kukjin Kim Acked-by: Eduardo Valentin Signed-off-by: Amit Daniel Kachhap Signed-off-by: Eduardo Valentin --- drivers/thermal/samsung/exynos_tmu.c | 13 +++++++++---- 1 file changed, 9 insertions(+), 4 deletions(-) (limited to 'drivers/thermal/samsung') diff --git a/drivers/thermal/samsung/exynos_tmu.c b/drivers/thermal/samsung/exynos_tmu.c index 651f4609ebb5..3fac0f92bf91 100644 --- a/drivers/thermal/samsung/exynos_tmu.c +++ b/drivers/thermal/samsung/exynos_tmu.c @@ -180,10 +180,15 @@ static int exynos_tmu_initialize(struct platform_device *pdev) data->temp_error2 = ((trim_info >> reg->triminfo_85_shift) & EXYNOS_TMU_TEMP_MASK); - if ((pdata->min_efuse_value > data->temp_error1) || - (data->temp_error1 > pdata->max_efuse_value) || - (data->temp_error2 != 0)) - data->temp_error1 = pdata->efuse_value; + if (!data->temp_error1 || + (pdata->min_efuse_value > data->temp_error1) || + (data->temp_error1 > pdata->max_efuse_value)) + data->temp_error1 = pdata->efuse_value & EXYNOS_TMU_TEMP_MASK; + + if (!data->temp_error2) + data->temp_error2 = + (pdata->efuse_value >> reg->triminfo_85_shift) & + EXYNOS_TMU_TEMP_MASK; if (pdata->max_trigger_level > MAX_THRESHOLD_LEVS) { dev_err(&pdev->dev, "Invalid max trigger level\n"); -- cgit v1.2.3