2018-03-08firmware: tegra: Simplify channel managementMikko Perttunen1-2/+2
The Tegra194 BPMP only implements 5 channels (4 to BPMP, 1 to CCPLEX), and they are not placed contiguously in memory. The current channel management in the BPMP driver does not support this. Simplify and refactor the channel management such that only one atomic transmit channel and one receive channel are supported, and channels are not required to be placed contiguously in memory. The same configuration also works on T186 so we end up with less code. Signed-off-by: Mikko Perttunen <mperttunen@nvidia.com> Signed-off-by: Thierry Reding <treding@nvidia.com>
2017-10-19firmware: tegra: Add BPMP debugfs supportTimo Alho1-0/+14
Tegra power management firmware running on the co-processor (BPMP) implements a simple pseudo file system akin to debugfs. The file system can be used for debugging purposes to examine and change the status of selected resources controlled by the firmware (such as clocks, resets, voltages, powergates, ...). Add support to "mirror" the firmware's file system to debugfs. At boot, query firmware for a list of all possible files and create corresponding debugfs entries. Read/write of individual files is implemented by sending a Message ReQuest (MRQ) that passes the full file path name and data to firmware via DRAM. Signed-off-by: Timo Alho <talho@nvidia.com> Reviewed-by: Jon Hunter <jonathanh@nvidia.com> Signed-off-by: Thierry Reding <treding@nvidia.com>
2017-10-19firmware: tegra: Add stubs when BPMP not enabledMikko Perttunen1-3/+39
Add static inline stubs to bpmp.h when CONFIG_BPMP is not enabled. This allows building BPMP-related drivers with COMPILE_TEST. Signed-off-by: Mikko Perttunen <mperttunen@nvidia.com> Signed-off-by: Thierry Reding <treding@nvidia.com>
2017-10-19firmware: tegra: Expose tegra_bpmp_mrq_return()Mikko Perttunen1-0/+2
Expose and export the tegra_bpmp_mrq_return() function for use by drivers outside the core BPMP driver. This function is used to reply to messages originating from the BPMP, which is required in the thermal driver. Signed-off-by: Mikko Perttunen <mperttunen@nvidia.com> Signed-off-by: Thierry Reding <treding@nvidia.com>
2017-10-17firmware: tegra: Propagate error code to callerTimo Alho1-0/+1
Response messages from Tegra BPMP firmware contain an error return code as the first word of payload. The error code is used to indicate incorrectly formatted request message or use of non-existing resource (clk, reset, powergate) identifier. Current implementation of tegra_bpmp_transfer() ignores this code and does not pass it to caller. Fix this by adding an extra struct member to tegra_bpmp_message and populate that with return code. Signed-off-by: Timo Alho <talho@nvidia.com> Acked-by: Jon Hunter <jonathanh@nvidia.com> Signed-off-by: Thierry Reding <treding@nvidia.com>
2017-06-13soc/tegra: bpmp: Implement generic PM domainsThierry Reding1-0/+12
The BPMP firmware, found on Tegra186 and later, provides an ABI that can be used to enable and disable power to several power partitions in Tegra SoCs. The ABI allows for enumeration of the available power partitions, so the driver can be reused on future generations, provided the BPMP ABI remains stable. Based on work by Stefan Kristiansson <stefank@nvidia.com> and Mikko Perttunen <mperttunen@nvidia.com>. Signed-off-by: Thierry Reding <treding@nvidia.com> Reviewed-by: Ulf Hansson <ulf.hansson@linaro.org> Signed-off-by: Thierry Reding <treding@nvidia.com>
2016-11-18firmware: tegra: Add BPMP supportThierry Reding1-0/+141
The Boot and Power Management Processor (BPMP) is a co-processor found on Tegra SoCs. It is designed to handle the early stages of the boot process and offload power management tasks (such as clocks, resets, powergates, ...) as well as system control services. Compared to the ARM SCPI, the services provided by BPMP are message- based rather than method-based. The BPMP firmware driver provides the services to transmit data to and receive data from the BPMP. Users can also register a Message ReQuest (MRQ), for which a service routine will be run when a corresponding event is received from the firmware. A set of messages, called the BPMP ABI, are specified for a number of different services provided by the BPMP (such as clocks or resets). Based on work by Sivaram Nair <sivaramn@nvidia.com> and Joseph Lo <josephl@nvidia.com>. Signed-off-by: Thierry Reding <treding@nvidia.com>