Age | Commit message (Collapse) | Author | Files | Lines |
|
Some motherboards like the Advantech ARK3400 documentation
use a non-inverted GPIO pin. We fix this by assuming that
the BIOS will set the Polarity bit for the GPIO correctly
at startup and we keep the Bit-setting intact when we start
and stop the watchdog.
Reported-by: Jean-François Deverge <jf.deverge@gmail.com>
Signed-off-by: Dave Mueller <d.mueller@elsoft.ch>
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
|
|
The SCH311x chip contains 2 watchdogs. One is the watchdog programmable
by the runtime register at address 0x65-0x68, the other is the watchdog
inside the power on reset generator. This second watchdog has a fixed
timeout value of ~1.6 seconds and is configurable only by the RESGEN
register.
The BIOS normally takes care of the RESGEN watchdog and disables it (at
least) before the OS is booted.
Unfortunately the sch311x_wdt driver clears bit 0 of the RESGEN register
which has the effect that at the latest 1.6 seconds later, a POR is
triggered.
The attached patch fixes this problem by completely removing any
reference to the RESGEN watchdog from the sch311x_wdt driver.
Signed-off-by: Dave Mueller <d.mueller@elsoft.ch>
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
|
|
nowayout is actually a boolean value.
So make it bool for all watchdog device drivers.
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
|
|
Use the current logging styles.
Make sure all output has a prefix.
Add missing newlines.
Remove now unnecessary PFX, NAME, and miscellaneous other #defines.
Coalesce formats.
Signed-off-by: Joe Perches <joe@perches.com>
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
|
|
While checking what watchdog drivers usually do in suspend/resume to
spot common behaviour for the watchdog framework, I found these drivers
which do nothing but add some cruft. Remove it, it is superfluous. New
approaches should probably be done with pm_ops anyway.
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de>
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
|
|
Fixes generated by 'codespell' and manually reviewed.
Signed-off-by: Lucas De Marchi <lucas.demarchi@profusion.mobi>
|
|
"==" has higher precedence than "&". Since
if (sch311x_sio_inb(sio_config_port, 0x30) & (0x01 == 0)) is always
false the message is never printed.
Signed-off-by: Dan Carpenter <error27@gmail.com>
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
|
|
if (sch311x_sio_inb(sio_config_port, 0x30) && 0x01 == 0) -> && should be &
Reported-By: Toralf Förster <toralf.foerster@gmx.de>
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
|
|
probe() function
Set the paranet of the misc_device before we register the misc_device.
Reported-by: Akinobu Mita <akinobu.mita@gmail.com>
Signed-off-by: Wim Van sebroeck <wim@iguana.be>
|
|
make the watchdog_info struct const where possible.
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
|
|
Add a watchdog driver for the hardware watchdog timer on the
SMSC SCH3112, SCH3114 and SCH3116 Super IO chipset.
Tested-by: Marco Chiappero <marco@absence.it>
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
|