2022-02-28power: supply: ab8500: Standardize BTI resistanceLinus Walleij1-12/+0
The Battery Type Indicator (BTI) resistor is a resistor mounted between a special terminal on the battery and ground. By sending a fixed current (such as 7mA) through this resistor and measuring the voltage over it, the resistance can be determined, and this verifies the battery type. Typical side view of the battery: o o o GND BTI +3.8V Typical example of the electrical layout: +3.8 V BTI | | | + | _______ [ ] 7kOhm ___ | | | | | GND GND By verifying this resistance before attempting to charge the battery we add an additional level of security. In some systems this is used for plug-and-play of batteries with different capacity. In other cases, this is merely used to verify that the right type of battery is connected, if several batteries have the same physical shape and can be plugged into the same slot. Sometimes this is just a surplus security mechanism. Nokia and Samsung among many other vendors are known to use these BTI resistors. Add the BTI properties to struct power_supply_battery_info and switch the AB8500 charger code over to using it. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2022-02-28power: supply: ab8500: Standardize alert mode chargingLinus Walleij1-4/+0
The AB8500 code is using a special current and voltage setting when the battery is in "alert mode", i.e. when it is starting to go outside normal operating conditions so it is too cold or too hot. This makes sense as a way for the charging algorithm to deal with hostile environments. Add the needed members to the struct power_supply_battery_info, and switch the AB8500 charging code over to using this. Reviewed-by: Matti Vaittineen <matti.vaittinen@fi.rohmeurope.com> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2022-02-28power: supply: ab8500: Standardize maintenance chargingLinus Walleij1-14/+0
Maintenance charging is the phase of keeping up the charge after the battery has charged fully using CC/CV charging. This can be done in many successive phases and is usually done with a slightly lower constant voltage than CV, and a slightly lower allowed current. Add an array of maintenance charging points each with a current, voltage and safety timer, and add helper functions to use these. Migrate the AB8500 code over. This is used in several Samsung products using the AB8500 and these batteries and their complete parameters will be added later as full examples, but the default battery in the AB8500 code serves as a reasonable example so far. Reviewed-by: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2022-02-11power: supply: ab8500: Integrate thermal zoneLinus Walleij1-33/+0
Instead of providing our own homebrewn thermal measurement code for an NTC and passing tables, we put the NTC thermistor into the device tree, create a passive thermal zone, and poll this thermal zone for the temperature. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2022-02-11power: supply: ab8500: Drop BATCTRL thermal modeLinus Walleij1-16/+0
The BATCTRL mode reads the temperature of the battery by enabling a certain probing current (7-20 mA) and then measure the voltage of the NTC mounted inside the battery. None of the AB8500 product or the reference designs use this mode. What we use is the so-called BATTEMP mode which enables an internal 230 kOhm pull-up to 1.8 V to the external NTC on pin BatTemp (N16) and then measures the voltage over the NTC using the ADC: 1.8V (VTVOUT) | [ ] 230 kOhm | BatTemp +---------------- ADC Pin N16 | _ |/ [/] NTC _/| | GND Cut out the BATCTRL code to clear the forest and stop maintaining code we can never test. The current inducing method is still used to probe for the battery type using the internal BTI (battery type indicator) on the BatCtrl (C3) pin in a separate code path. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2022-01-03power: supply_core: Pass pointer to battery infoLinus Walleij1-1/+1
The function to retrieve battery info (from the device tree) assumes we have a static info struct that gets populated by calling into power_supply_get_battery_info(). This is awkward since I want to support tables of static battery info by just assigning a pointer to all info based on e.g. a compatible value in the device tree. We also have a mixture of static and dynamically allocated variables here. Bite the bullet and let power_supply_get_battery_info() allocate also the memory used for the very top level struct power_supply_battery_info container. Pass pointers around and lifecycle this with the psy device just like the stuff we allocate inside it. Change all current users over. As part of the change, initializers need to be added to some previously uninitialized fields in struct power_supply_battery_info. Reviewed-By: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-11-22power: supply: ab8500: Standardize capacity lookupLinus Walleij1-23/+7
The AB8500 charger only has one capacity table with unspecified temperature, so we assume this capacity is given for 20 degrees Celsius. Convert this table to use the OCV (open circuit voltage) tables in struct power_supply_battery_ocv_table. In the process, convert the fuel gauge driver to use microvolts and microamperes so we can use the same internals as the power supply subsystem without having to multiply and divide with 1000 in a few places. Also convert high_curr_threshold and lowbat_threshold to use microamperes and microvolts as these are closely related to these changes. Drop the unused overbat_threshold member in the custom struct ab8500_fg_parameters. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-11-22power: supply: ab8500: Standardize temp res lookupLinus Walleij1-15/+0
The lookup from battery temperature to internal resistance was using its own format. Rewrite this to use the table inside struct power_supply_battery_info:s resist_table. The supplied resistance table has to be rewritten to express the resistance in percent of the factory resistance as a side effect. We can then rely on the library function power_supply_temp2resist_simple() to interpolate the internal resistance percent from the temperature. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-11-22power: supply: ab8500: Standardize CV voltageLinus Walleij1-6/+4
The voltage used in the constant voltage phase of the charging exist in struct power_supply_battery_info as constant_charge_voltage_max_uv. Switch the custom property normal_vol_lvl to this and consequentially change everything that relates to this value over to using microvolts rather than millivolts so we align internal representation of current with the power core. Prefix every variable we change with *_uv to indicate the unit everywhere but also to make sure we do not miss any outlier. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-11-22power: supply: ab8500: Standardize CC currentLinus Walleij1-17/+8
The current used in the constant current phase of the charging exist in struct power_supply_battery_info as constant_charge_current_max_ua. Switch the custom property max_out_curr to this and consequentally change everything that relates to this value over to using microamperes rather than milliamperes so we align internal representation of current with the power core. Prefix every variable we change with *_ua to indicate the unit everywhere but also to make sure we do not miss any outlier. Drop some duplicate unused defines in a header. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-11-22power: supply: ab8500: Make recharge capacity a constantLinus Walleij1-4/+0
The recharge capacity is the hysteresis level for a charger to restart when a battery does not support maintenance charging. All products using the AB8500 have batteries supporting maintenace charging and all code has always set this to 95%. Turn it into a constant. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-11-22power: supply: ab8500: Standardize termination currentLinus Walleij1-2/+0
The AB8500 custom termination current can be replaced by the corresponding struct power_supply_battery_info field. Remove the struct member and amend the code to use the standard property. Add *_ua suffix for clarity and to make sure we have changed all code sites using this member. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-11-22power: supply: ab8500: Standardize internal resistanceLinus Walleij1-2/+0
The nominal internal resistance isn't used by the AB8500 charging code, instead this resistance is measured continuously, but we anyways migrate this to the standard property in struct power_supply_battery_info. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-11-22power: supply: ab8500: Standardize voltagesLinus Walleij1-4/+0
The nominal voltage in this charge driver corresponds to both the voltage_min_design_uv and voltage_max_design_uv of struct power_supply_battery_info so assign both if this is undefined. The overcharge max voltage (when the charger should cut off) is migrated at the same time so we move both voltages to struct power_supply_battery_info. Adjust the code to deal directly with the microvolt values instead of converting them to millivolts. Add *_uv suffixes for clarity and to make sure we have changed all code sites using this member. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-11-22power: supply: ab8500: Standardize technologyLinus Walleij1-2/+0
The AB8500 custom battery type can be replaced by the corresponding struct power_supply_battery_info field. Remove the struct member and amend the code to use the standard property. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-11-22power: supply: ab8500: Standardize design capacityLinus Walleij1-2/+0
Now that we know that we have only one battery type to deal with we can proceed to transfer properties to struct power_supply_battery_info. The designed capacity for the battery was in a custom field of the custom battery type in mAh, transfer this to the standard charge_full_design_uah property in struct power_supply_battery_info and augment the code accordingly. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-11-22power: supply: ab8500: Use only one battery typeLinus Walleij1-4/+0
The code was going through hoops and loops to detect what battery is connected and check the resistance for this battery etc. Skip this trouble: we will support one battery (currently "unknown") then we will find the connected battery in the device tree using a compatible string. The battery resistance may be used to double-check that the right battery is connected. Convert the array of battery types into one battery type so we can next move over the properties of this one type into the standard struct power_supply_battery_info. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-11-22power: supply: ab8500: Standardize operating temperatureLinus Walleij1-8/+4
Instead of storing the temperature limits in our custom struct struct ab8500_bm_data, make struct power_supply_battery_info a member of this and store the min and max temperatures inside that struct as the temp_min/temp_max and temp_alert_min/temp_alert_max respectively. The values can be assigned from the device tree, but if not present will be set to the same defaults as are currently in the code. This way we start to move over to using struct power_supply_battery_info and make it possible to move the data over to the device tree and we will move piece by piece toward using the standard info struct. Temperature hysteresis is currently not supported by the standard struct but we move the assignment here as well so that we have all parameterization in one spot. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-11-22power: supply: ab8500: Sink current tables into charger codeLinus Walleij1-8/+0
The two tables for input and output current translation from register values does not need to be passed around from the battery manager data. Just push it down into the charger code where it is used, like other tables in that code. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-11-22power: supply: ab8500: Use core battery parserLinus Walleij1-2/+1
This deploys the core battery DT parser to read the basic properties of the battery. We only use very little of it as we start out, but we will improve as we go along. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-07-16power: supply: ab8500: Drop abx500 conceptLinus Walleij1-185/+32
Drop the entire idea with abx500 being abstract and different from ab8500 in the AB8500 charging drivers. This rids the two identical definitions of a slew of structs in ab8500-bm.h and makes things less confusion and easier to understand. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-07-16power: supply: ab8500: Rename charging algorithm symbolsLinus Walleij1-1/+1
The "abx500" name on the charging algorithm stems from the ambition to produce a series of these analog basebands, re-using the same charging algorithm driver. No ASICs beside AB8500 and AB8505 were ever produced so this terminology is confusing. Rename the algorithm file and symbols to reflect the more narrow scope. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-06-03power: supply: ab8500: Drop unused memberLinus Walleij1-1/+0
This setting is read directly from the device tree in the ab8500_charger.c code. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-06-03power: supply: ab8500: Enable USB and ACLinus Walleij1-2/+0
The vendor code tree supplies platform data to enable he USB charging for AB8500 and AB8500 and disable the AC charging on the AB8505. This was missed when the driver was submitted to the mainline kernel. Fix this by doing what the vendor kernel does: always register the USB charger, do not register the AC charger on the AB8505. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-06-03power: supply: ab8500: Move to componentized bindingLinus Walleij1-0/+4
The driver has problems with the different components of the charging code racing with each other to probe(). This results in all four subdrivers populating battery information to ascertain that it is populated for their own needs for example. Fix this by using component probing and thus expressing to the kernel that these are dependent components. The probes can happen in any order and will only acquire resources such as state container, regulators and interrupts and initialize the data structures, but no execution happens until the .bind() callback is called. The charging driver is the main component and binds first, then bind in order the three subcomponents: ab8500-fg, ab8500-btemp and ab8500-chargalg. Do some housekeeping while we are moving the code around. Like use devm_* for IRQs so as to cut down on some boilerplate. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-03-22mfd/power: ab8500: Push data to power supply codeLinus Walleij1-4/+274
There is a slew of defines, structs and enums and even a function call only relevant for the charging code that still lives in <linux/mfd/abx500.h>. Push it down to the "ab8500-bm.h" header in the power supply subsystem where it is actually used. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Acked-by: Sebastian Reichel <sebastian.reichel@collabora.com> Signed-off-by: Lee Jones <lee.jones@linaro.org>
2021-03-22mfd/power: ab8500: Push data to power supply codeLinus Walleij1-0/+463
The global definition of platform data for the battery management code has no utility after the OF conversion, move the <linux/mfd/abx500/ab8500-bm.h> to be a local file in drivers/power/supply and stop defining the platform data in drivers/power/supply/ab8500_bmdata.c and broadcast to the kernel only to have it assigned as platform data to the MFD cells and then picked back into the same subsystem that defined it in the first place. This kills off a layer of indirection. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Acked-by: Sebastian Reichel <sebastian.reichel@collabora.com> Signed-off-by: Lee Jones <lee.jones@linaro.org>