summaryrefslogtreecommitdiff
path: root/drivers/hwmon/pmbus/pmbus.h
AgeCommit message (Collapse)AuthorFilesLines
2011-07-29hwmon: (pmbus) Add client driver for LM25066, LM5064, and LM5066Guenter Roeck1-0/+1
PMBus client driver supporting National Semiconductor LM25066, LM5064, and LM5066. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-29hwmon: (pmbus) Add support for peak attributesGuenter Roeck1-0/+36
Most PMBus devices provide manufacturer specific commands to read low and/or high peak values for some or all of its sensors. To support providing those values as lowest/highest attributes to the user, introduce virtual PMBus commands. Those commands reside outside the normal command set and have to be implemented in device specific code, which map the virtual commands to device specific commands. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-29hwmon: (pmbus) Add support for virtual pagesGuenter Roeck1-1/+1
Some PMBus chips have non-standard sensor registers. An easy way to support such sensors is to introduce virtual pages and map the non-standard registers into standard registers on an extra page. For this to work, the code verifying if the configured number of pages exists has to be removed. Since a wrong number of pages can only be configured in a front-end driver, this should not have a practical impact since the resulting errors should be found during development and testing. Also, functions to read the chip status while checking if a command register exists must be modified to no longer set the page register before reading the status, since the physical page associated with the checked register may not exist. This does not make a functional difference since the page was already set when the attempt to read the register was made. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-29hwmon: (pmbus) Support reading and writing of word registers in device ↵Guenter Roeck1-0/+4
specific code Some PMBus devices use non-standard registers for some of the sensors and/or limits. To support such devices, add code to support reading and writing of word size registers in device specific code. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-29hwmon: (pmbus) Add support for VID output voltage modeGuenter Roeck1-3/+4
In VID mode, output voltages are measured and reported as VID values, and have to be converted to voltages using VID conversion tables or functions. Support is added for VR11 only at this time. This patch enables support for PMBus devices supporting VID VR11 based output voltage selection such as NCP4200 and NCP4208. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Move PMBus drivers to drivers/hwmon/pmbusGuenter Roeck1-0/+311
Since the number of PMBus drivers is getting large, move them into directory drivers/hwmon/pmbus to improve readability and scalability. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>