diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h
index 40b4ef54cc7d..77c87c9d0193 100644
--- a/include/linux/cpu_cooling.h
+++ b/include/linux/cpu_cooling.h
@@ -29,7 +29,7 @@
#define CPUFREQ_COOLING_START 0
#define CPUFREQ_COOLING_STOP 1
-#if defined(CONFIG_CPU_THERMAL) || defined(CONFIG_CPU_THERMAL_MODULE)
+#ifdef CONFIG_CPU_THERMAL
/**
* cpufreq_cooling_register - function to create cpufreq cooling device.
* @clip_cpus: cpumask of cpus where the frequency constraints will happen
@@ -42,6 +42,8 @@ struct thermal_cooling_device *cpufreq_cooling_register(
* @cdev: thermal cooling device pointer.
*/
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev);
+
+unsigned long cpufreq_cooling_get_level(unsigned int, unsigned int);
#else /* !CONFIG_CPU_THERMAL */
static inline struct thermal_cooling_device *cpufreq_cooling_register(
const struct cpumask *clip_cpus)
@@ -53,6 +55,11 @@ static inline void cpufreq_cooling_unregister(
{
return;
}
+static inline unsigned long cpufreq_cooling_get_level(unsigned int,
+ unsigned int)
+{
+ return THERMAL_CSTATE_INVALID;
+}
#endif /* CONFIG_CPU_THERMAL */
#endif /* __CPU_COOLING_H__ */
diff --git a/include/linux/thermal.h b/include/linux/thermal.h
index fd7b8f3e6f42..3bda306f7a50 100644
--- a/include/linux/thermal.h
+++ b/include/linux/thermal.h
@@ -33,8 +33,11 @@
#define THERMAL_MAX_TRIPS 12
#define THERMAL_NAME_LENGTH 20
+/* invalid cooling state */
+#define THERMAL_CSTATE_INVALID -1UL
+
/* No upper/lower limit requirement */
-#define THERMAL_NO_LIMIT -1UL
+#define THERMAL_NO_LIMIT THERMAL_CSTATE_INVALID
/* Unit conversion macros */
#define KELVIN_TO_CELSIUS(t) (long)(((long)t-2732 >= 0) ? \
@@ -184,7 +187,6 @@ struct thermal_governor {
char name[THERMAL_NAME_LENGTH];
int (*throttle)(struct thermal_zone_device *tz, int trip);
struct list_head governor_list;
- struct module *owner;
};
/* Structure that holds binding parameters for a zone */
@@ -244,9 +246,6 @@ struct thermal_instance *get_thermal_instance(struct thermal_zone_device *,
void thermal_cdev_update(struct thermal_cooling_device *);
void notify_thermal_framework(struct thermal_zone_device *, int);
-int thermal_register_governor(struct thermal_governor *);
-void thermal_unregister_governor(struct thermal_governor *);
-
#ifdef CONFIG_NET
extern int thermal_generate_netlink_event(struct thermal_zone_device *tz,
enum events event);