summaryrefslogtreecommitdiff
path: root/drivers/thermal/cpu_cooling.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/thermal/cpu_cooling.c')
-rw-r--r--drivers/thermal/cpu_cooling.c22
1 files changed, 10 insertions, 12 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index 2c2d76ac04c3..bfa9731e7cdb 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -87,7 +87,6 @@ struct time_in_idle {
* @node: list_head to link all cpufreq_cooling_device together.
* @last_load: load measured by the latest call to cpufreq_get_requested_power()
* @idle_time: idle time stats
- * @cpu_dev: the cpu_device of policy->cpu.
* @plat_get_static_power: callback to calculate the static power
*
* This structure is required for keeping information of each registered
@@ -104,7 +103,6 @@ struct cpufreq_cooling_device {
struct list_head node;
u32 last_load;
struct time_in_idle *idle_time;
- struct device *cpu_dev;
get_static_t plat_get_static_power;
};
@@ -259,8 +257,6 @@ static int update_freq_table(struct cpufreq_cooling_device *cpufreq_cdev,
freq_table[i].power = power;
}
- cpufreq_cdev->cpu_dev = dev;
-
return 0;
}
@@ -342,19 +338,22 @@ static int get_static_power(struct cpufreq_cooling_device *cpufreq_cdev,
{
struct dev_pm_opp *opp;
unsigned long voltage;
- struct cpumask *cpumask = cpufreq_cdev->policy->related_cpus;
+ struct cpufreq_policy *policy = cpufreq_cdev->policy;
+ struct cpumask *cpumask = policy->related_cpus;
unsigned long freq_hz = freq * 1000;
+ struct device *dev;
- if (!cpufreq_cdev->plat_get_static_power || !cpufreq_cdev->cpu_dev) {
+ if (!cpufreq_cdev->plat_get_static_power) {
*power = 0;
return 0;
}
- opp = dev_pm_opp_find_freq_exact(cpufreq_cdev->cpu_dev, freq_hz,
- true);
+ dev = get_cpu_device(policy->cpu);
+ WARN_ON(!dev);
+
+ opp = dev_pm_opp_find_freq_exact(dev, freq_hz, true);
if (IS_ERR(opp)) {
- dev_warn_ratelimited(cpufreq_cdev->cpu_dev,
- "Failed to find OPP for frequency %lu: %ld\n",
+ dev_warn_ratelimited(dev, "Failed to find OPP for frequency %lu: %ld\n",
freq_hz, PTR_ERR(opp));
return -EINVAL;
}
@@ -363,8 +362,7 @@ static int get_static_power(struct cpufreq_cooling_device *cpufreq_cdev,
dev_pm_opp_put(opp);
if (voltage == 0) {
- dev_err_ratelimited(cpufreq_cdev->cpu_dev,
- "Failed to get voltage for frequency %lu\n",
+ dev_err_ratelimited(dev, "Failed to get voltage for frequency %lu\n",
freq_hz);