summaryrefslogtreecommitdiff
path: root/drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c')
-rw-r--r--drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c74
1 files changed, 41 insertions, 33 deletions
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c
index 53fb4fa61b40..549549eaf580 100644
--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c
@@ -154,15 +154,22 @@ typedef int (*read_sfp_module_eeprom_func_p)(struct bnx2x_phy *phy,
LINK_STATUS_LINK_PARTNER_ASYMMETRIC_PAUSE)
#define SFP_EEPROM_CON_TYPE_ADDR 0x2
+ #define SFP_EEPROM_CON_TYPE_VAL_UNKNOWN 0x0
#define SFP_EEPROM_CON_TYPE_VAL_LC 0x7
#define SFP_EEPROM_CON_TYPE_VAL_COPPER 0x21
#define SFP_EEPROM_CON_TYPE_VAL_RJ45 0x22
-#define SFP_EEPROM_COMP_CODE_ADDR 0x3
- #define SFP_EEPROM_COMP_CODE_SR_MASK (1<<4)
- #define SFP_EEPROM_COMP_CODE_LR_MASK (1<<5)
- #define SFP_EEPROM_COMP_CODE_LRM_MASK (1<<6)
+#define SFP_EEPROM_10G_COMP_CODE_ADDR 0x3
+ #define SFP_EEPROM_10G_COMP_CODE_SR_MASK (1<<4)
+ #define SFP_EEPROM_10G_COMP_CODE_LR_MASK (1<<5)
+ #define SFP_EEPROM_10G_COMP_CODE_LRM_MASK (1<<6)
+
+#define SFP_EEPROM_1G_COMP_CODE_ADDR 0x6
+ #define SFP_EEPROM_1G_COMP_CODE_SX (1<<0)
+ #define SFP_EEPROM_1G_COMP_CODE_LX (1<<1)
+ #define SFP_EEPROM_1G_COMP_CODE_CX (1<<2)
+ #define SFP_EEPROM_1G_COMP_CODE_BASE_T (1<<3)
#define SFP_EEPROM_FC_TX_TECH_ADDR 0x8
#define SFP_EEPROM_FC_TX_TECH_BITMASK_COPPER_PASSIVE 0x4
@@ -3633,8 +3640,8 @@ static void bnx2x_warpcore_enable_AN_KR2(struct bnx2x_phy *phy,
reg_set[i].val);
/* Start KR2 work-around timer which handles BCM8073 link-parner */
- vars->link_attr_sync |= LINK_ATTR_SYNC_KR2_ENABLE;
- bnx2x_update_link_attr(params, vars->link_attr_sync);
+ params->link_attr_sync |= LINK_ATTR_SYNC_KR2_ENABLE;
+ bnx2x_update_link_attr(params, params->link_attr_sync);
}
static void bnx2x_disable_kr2(struct link_params *params,
@@ -3666,8 +3673,8 @@ static void bnx2x_disable_kr2(struct link_params *params,
for (i = 0; i < ARRAY_SIZE(reg_set); i++)
bnx2x_cl45_write(bp, phy, reg_set[i].devad, reg_set[i].reg,
reg_set[i].val);
- vars->link_attr_sync &= ~LINK_ATTR_SYNC_KR2_ENABLE;
- bnx2x_update_link_attr(params, vars->link_attr_sync);
+ params->link_attr_sync &= ~LINK_ATTR_SYNC_KR2_ENABLE;
+ bnx2x_update_link_attr(params, params->link_attr_sync);
vars->check_kr2_recovery_cnt = CHECK_KR2_RECOVERY_CNT;
}
@@ -4810,7 +4817,7 @@ void bnx2x_link_status_update(struct link_params *params,
~FEATURE_CONFIG_PFC_ENABLED;
if (SHMEM2_HAS(bp, link_attr_sync))
- vars->link_attr_sync = SHMEM2_RD(bp,
+ params->link_attr_sync = SHMEM2_RD(bp,
link_attr_sync[params->port]);
DP(NETIF_MSG_LINK, "link_status 0x%x phy_link_up %x int_mask 0x%x\n",
@@ -8057,21 +8064,24 @@ static int bnx2x_get_edc_mode(struct bnx2x_phy *phy,
{
struct bnx2x *bp = params->bp;
u32 sync_offset = 0, phy_idx, media_types;
- u8 gport, val[2], check_limiting_mode = 0;
+ u8 val[SFP_EEPROM_FC_TX_TECH_ADDR + 1], check_limiting_mode = 0;
*edc_mode = EDC_MODE_LIMITING;
phy->media_type = ETH_PHY_UNSPECIFIED;
/* First check for copper cable */
if (bnx2x_read_sfp_module_eeprom(phy,
params,
I2C_DEV_ADDR_A0,
- SFP_EEPROM_CON_TYPE_ADDR,
- 2,
+ 0,
+ SFP_EEPROM_FC_TX_TECH_ADDR + 1,
(u8 *)val) != 0) {
DP(NETIF_MSG_LINK, "Failed to read from SFP+ module EEPROM\n");
return -EINVAL;
}
-
- switch (val[0]) {
+ params->link_attr_sync &= ~LINK_SFP_EEPROM_COMP_CODE_MASK;
+ params->link_attr_sync |= val[SFP_EEPROM_10G_COMP_CODE_ADDR] <<
+ LINK_SFP_EEPROM_COMP_CODE_SHIFT;
+ bnx2x_update_link_attr(params, params->link_attr_sync);
+ switch (val[SFP_EEPROM_CON_TYPE_ADDR]) {
case SFP_EEPROM_CON_TYPE_VAL_COPPER:
{
u8 copper_module_type;
@@ -8079,17 +8089,7 @@ static int bnx2x_get_edc_mode(struct bnx2x_phy *phy,
/* Check if its active cable (includes SFP+ module)
* of passive cable
*/
- if (bnx2x_read_sfp_module_eeprom(phy,
- params,
- I2C_DEV_ADDR_A0,
- SFP_EEPROM_FC_TX_TECH_ADDR,
- 1,
- &copper_module_type) != 0) {
- DP(NETIF_MSG_LINK,
- "Failed to read copper-cable-type"
- " from SFP+ EEPROM\n");
- return -EINVAL;
- }
+ copper_module_type = val[SFP_EEPROM_FC_TX_TECH_ADDR];
if (copper_module_type &
SFP_EEPROM_FC_TX_TECH_BITMASK_COPPER_ACTIVE) {
@@ -8115,16 +8115,18 @@ static int bnx2x_get_edc_mode(struct bnx2x_phy *phy,
}
break;
}
+ case SFP_EEPROM_CON_TYPE_VAL_UNKNOWN:
case SFP_EEPROM_CON_TYPE_VAL_LC:
case SFP_EEPROM_CON_TYPE_VAL_RJ45:
check_limiting_mode = 1;
- if ((val[1] & (SFP_EEPROM_COMP_CODE_SR_MASK |
- SFP_EEPROM_COMP_CODE_LR_MASK |
- SFP_EEPROM_COMP_CODE_LRM_MASK)) == 0) {
+ if ((val[SFP_EEPROM_10G_COMP_CODE_ADDR] &
+ (SFP_EEPROM_10G_COMP_CODE_SR_MASK |
+ SFP_EEPROM_10G_COMP_CODE_LR_MASK |
+ SFP_EEPROM_10G_COMP_CODE_LRM_MASK)) == 0) {
DP(NETIF_MSG_LINK, "1G SFP module detected\n");
- gport = params->port;
phy->media_type = ETH_PHY_SFP_1G_FIBER;
if (phy->req_line_speed != SPEED_1000) {
+ u8 gport = params->port;
phy->req_line_speed = SPEED_1000;
if (!CHIP_IS_E1x(bp)) {
gport = BP_PATH(bp) +
@@ -8134,6 +8136,12 @@ static int bnx2x_get_edc_mode(struct bnx2x_phy *phy,
"Warning: Link speed was forced to 1000Mbps. Current SFP module in port %d is not compliant with 10G Ethernet\n",
gport);
}
+ if (val[SFP_EEPROM_1G_COMP_CODE_ADDR] &
+ SFP_EEPROM_1G_COMP_CODE_BASE_T) {
+ bnx2x_sfp_set_transmitter(params, phy, 0);
+ msleep(40);
+ bnx2x_sfp_set_transmitter(params, phy, 1);
+ }
} else {
int idx, cfg_idx = 0;
DP(NETIF_MSG_LINK, "10G Optic module detected\n");
@@ -8149,7 +8157,7 @@ static int bnx2x_get_edc_mode(struct bnx2x_phy *phy,
break;
default:
DP(NETIF_MSG_LINK, "Unable to determine module type 0x%x !!!\n",
- val[0]);
+ val[SFP_EEPROM_CON_TYPE_ADDR]);
return -EINVAL;
}
sync_offset = params->shmem_base +
@@ -13507,7 +13515,7 @@ static void bnx2x_check_kr2_wa(struct link_params *params,
sigdet = bnx2x_warpcore_get_sigdet(phy, params);
if (!sigdet) {
- if (!(vars->link_attr_sync & LINK_ATTR_SYNC_KR2_ENABLE)) {
+ if (!(params->link_attr_sync & LINK_ATTR_SYNC_KR2_ENABLE)) {
bnx2x_kr2_recovery(params, vars, phy);
DP(NETIF_MSG_LINK, "No sigdet\n");
}
@@ -13525,7 +13533,7 @@ static void bnx2x_check_kr2_wa(struct link_params *params,
/* CL73 has not begun yet */
if (base_page == 0) {
- if (!(vars->link_attr_sync & LINK_ATTR_SYNC_KR2_ENABLE)) {
+ if (!(params->link_attr_sync & LINK_ATTR_SYNC_KR2_ENABLE)) {
bnx2x_kr2_recovery(params, vars, phy);
DP(NETIF_MSG_LINK, "No BP\n");
}
@@ -13541,7 +13549,7 @@ static void bnx2x_check_kr2_wa(struct link_params *params,
((next_page & 0xe0) == 0x20))));
/* In case KR2 is already disabled, check if we need to re-enable it */
- if (!(vars->link_attr_sync & LINK_ATTR_SYNC_KR2_ENABLE)) {
+ if (!(params->link_attr_sync & LINK_ATTR_SYNC_KR2_ENABLE)) {
if (!not_kr2_device) {
DP(NETIF_MSG_LINK, "BP=0x%x, NP=0x%x\n", base_page,
next_page);