summaryrefslogtreecommitdiff
path: root/drivers/cpufreq/cpufreq-dt.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/cpufreq/cpufreq-dt.c')
-rw-r--r--drivers/cpufreq/cpufreq-dt.c69
1 files changed, 44 insertions, 25 deletions
diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c
index f657c571b18e..f56147a1daed 100644
--- a/drivers/cpufreq/cpufreq-dt.c
+++ b/drivers/cpufreq/cpufreq-dt.c
@@ -58,6 +58,8 @@ static int set_target(struct cpufreq_policy *policy, unsigned int index)
old_freq = clk_get_rate(cpu_clk) / 1000;
if (!IS_ERR(cpu_reg)) {
+ unsigned long opp_freq;
+
rcu_read_lock();
opp = dev_pm_opp_find_freq_ceil(cpu_dev, &freq_Hz);
if (IS_ERR(opp)) {
@@ -67,13 +69,16 @@ static int set_target(struct cpufreq_policy *policy, unsigned int index)
return PTR_ERR(opp);
}
volt = dev_pm_opp_get_voltage(opp);
+ opp_freq = dev_pm_opp_get_freq(opp);
rcu_read_unlock();
tol = volt * priv->voltage_tolerance / 100;
volt_old = regulator_get_voltage(cpu_reg);
+ dev_dbg(cpu_dev, "Found OPP: %ld kHz, %ld uV\n",
+ opp_freq / 1000, volt);
}
dev_dbg(cpu_dev, "%u MHz, %ld mV --> %u MHz, %ld mV\n",
- old_freq / 1000, volt_old ? volt_old / 1000 : -1,
+ old_freq / 1000, (volt_old > 0) ? volt_old / 1000 : -1,
new_freq / 1000, volt ? volt / 1000 : -1);
/* scaling up? scale voltage before frequency */
@@ -89,7 +94,7 @@ static int set_target(struct cpufreq_policy *policy, unsigned int index)
ret = clk_set_rate(cpu_clk, freq_exact);
if (ret) {
dev_err(cpu_dev, "failed to set clock rate: %d\n", ret);
- if (!IS_ERR(cpu_reg))
+ if (!IS_ERR(cpu_reg) && volt_old > 0)
regulator_set_voltage_tol(cpu_reg, volt_old, tol);
return ret;
}
@@ -181,7 +186,6 @@ static int cpufreq_init(struct cpufreq_policy *policy)
{
struct cpufreq_dt_platform_data *pd;
struct cpufreq_frequency_table *freq_table;
- struct thermal_cooling_device *cdev;
struct device_node *np;
struct private_data *priv;
struct device *cpu_dev;
@@ -193,7 +197,7 @@ static int cpufreq_init(struct cpufreq_policy *policy)
ret = allocate_resources(policy->cpu, &cpu_dev, &cpu_reg, &cpu_clk);
if (ret) {
- pr_err("%s: Failed to allocate resources\n: %d", __func__, ret);
+ pr_err("%s: Failed to allocate resources: %d\n", __func__, ret);
return ret;
}
@@ -210,7 +214,7 @@ static int cpufreq_init(struct cpufreq_policy *policy)
priv = kzalloc(sizeof(*priv), GFP_KERNEL);
if (!priv) {
ret = -ENOMEM;
- goto out_put_node;
+ goto out_free_opp;
}
of_property_read_u32(np, "voltage-tolerance", &priv->voltage_tolerance);
@@ -264,20 +268,6 @@ static int cpufreq_init(struct cpufreq_policy *policy)
goto out_free_priv;
}
- /*
- * For now, just loading the cooling device;
- * thermal DT code takes care of matching them.
- */
- if (of_find_property(np, "#cooling-cells", NULL)) {
- cdev = of_cpufreq_cooling_register(np, cpu_present_mask);
- if (IS_ERR(cdev))
- dev_err(cpu_dev,
- "running cpufreq without cooling device: %ld\n",
- PTR_ERR(cdev));
- else
- priv->cdev = cdev;
- }
-
priv->cpu_dev = cpu_dev;
priv->cpu_reg = cpu_reg;
policy->driver_data = priv;
@@ -287,7 +277,7 @@ static int cpufreq_init(struct cpufreq_policy *policy)
if (ret) {
dev_err(cpu_dev, "%s: invalid frequency table: %d\n", __func__,
ret);
- goto out_cooling_unregister;
+ goto out_free_cpufreq_table;
}
policy->cpuinfo.transition_latency = transition_latency;
@@ -300,12 +290,12 @@ static int cpufreq_init(struct cpufreq_policy *policy)
return 0;
-out_cooling_unregister:
- cpufreq_cooling_unregister(priv->cdev);
+out_free_cpufreq_table:
dev_pm_opp_free_cpufreq_table(cpu_dev, &freq_table);
out_free_priv:
kfree(priv);
-out_put_node:
+out_free_opp:
+ of_free_opp_table(cpu_dev);
of_node_put(np);
out_put_reg_clk:
clk_put(cpu_clk);
@@ -319,8 +309,10 @@ static int cpufreq_exit(struct cpufreq_policy *policy)
{
struct private_data *priv = policy->driver_data;
- cpufreq_cooling_unregister(priv->cdev);
+ if (priv->cdev)
+ cpufreq_cooling_unregister(priv->cdev);
dev_pm_opp_free_cpufreq_table(priv->cpu_dev, &policy->freq_table);
+ of_free_opp_table(priv->cpu_dev);
clk_put(policy->clk);
if (!IS_ERR(priv->cpu_reg))
regulator_put(priv->cpu_reg);
@@ -329,6 +321,33 @@ static int cpufreq_exit(struct cpufreq_policy *policy)
return 0;
}
+static void cpufreq_ready(struct cpufreq_policy *policy)
+{
+ struct private_data *priv = policy->driver_data;
+ struct device_node *np = of_node_get(priv->cpu_dev->of_node);
+
+ if (WARN_ON(!np))
+ return;
+
+ /*
+ * For now, just loading the cooling device;
+ * thermal DT code takes care of matching them.
+ */
+ if (of_find_property(np, "#cooling-cells", NULL)) {
+ priv->cdev = of_cpufreq_cooling_register(np,
+ policy->related_cpus);
+ if (IS_ERR(priv->cdev)) {
+ dev_err(priv->cpu_dev,
+ "running cpufreq without cooling device: %ld\n",
+ PTR_ERR(priv->cdev));
+
+ priv->cdev = NULL;
+ }
+ }
+
+ of_node_put(np);
+}
+
static struct cpufreq_driver dt_cpufreq_driver = {
.flags = CPUFREQ_STICKY | CPUFREQ_NEED_INITIAL_FREQ_CHECK,
.verify = cpufreq_generic_frequency_table_verify,
@@ -336,6 +355,7 @@ static struct cpufreq_driver dt_cpufreq_driver = {
.get = cpufreq_generic_get,
.init = cpufreq_init,
.exit = cpufreq_exit,
+ .ready = cpufreq_ready,
.name = "cpufreq-dt",
.attr = cpufreq_generic_attr,
};
@@ -380,7 +400,6 @@ static int dt_cpufreq_remove(struct platform_device *pdev)
static struct platform_driver dt_cpufreq_platdrv = {
.driver = {
.name = "cpufreq-dt",
- .owner = THIS_MODULE,
},
.probe = dt_cpufreq_probe,
.remove = dt_cpufreq_remove,