diff options
Diffstat (limited to 'arch/x86/kernel/amd_nb.c')
-rw-r--r-- | arch/x86/kernel/amd_nb.c | 164 |
1 files changed, 146 insertions, 18 deletions
diff --git a/arch/x86/kernel/amd_nb.c b/arch/x86/kernel/amd_nb.c index 4fdf6230d93c..458da8509b75 100644 --- a/arch/x86/kernel/amd_nb.c +++ b/arch/x86/kernel/amd_nb.c @@ -13,8 +13,20 @@ #include <linux/spinlock.h> #include <asm/amd_nb.h> +#define PCI_DEVICE_ID_AMD_17H_ROOT 0x1450 +#define PCI_DEVICE_ID_AMD_17H_DF_F3 0x1463 +#define PCI_DEVICE_ID_AMD_17H_DF_F4 0x1464 + +/* Protect the PCI config register pairs used for SMN and DF indirect access. */ +static DEFINE_MUTEX(smn_mutex); + static u32 *flush_words; +static const struct pci_device_id amd_root_ids[] = { + { PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_ROOT) }, + {} +}; + const struct pci_device_id amd_nb_misc_ids[] = { { PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_K8_NB_MISC) }, { PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_10H_NB_MISC) }, @@ -24,9 +36,10 @@ const struct pci_device_id amd_nb_misc_ids[] = { { PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_M60H_NB_F3) }, { PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_16H_NB_F3) }, { PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_16H_M30H_NB_F3) }, + { PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_DF_F3) }, {} }; -EXPORT_SYMBOL(amd_nb_misc_ids); +EXPORT_SYMBOL_GPL(amd_nb_misc_ids); static const struct pci_device_id amd_nb_link_ids[] = { { PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_NB_F4) }, @@ -34,6 +47,7 @@ static const struct pci_device_id amd_nb_link_ids[] = { { PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_M60H_NB_F4) }, { PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_16H_NB_F4) }, { PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_16H_M30H_NB_F4) }, + { PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_DF_F4) }, {} }; @@ -44,8 +58,25 @@ const struct amd_nb_bus_dev_range amd_nb_bus_dev_ranges[] __initconst = { { } }; -struct amd_northbridge_info amd_northbridges; -EXPORT_SYMBOL(amd_northbridges); +static struct amd_northbridge_info amd_northbridges; + +u16 amd_nb_num(void) +{ + return amd_northbridges.num; +} +EXPORT_SYMBOL_GPL(amd_nb_num); + +bool amd_nb_has_feature(unsigned int feature) +{ + return ((amd_northbridges.flags & feature) == feature); +} +EXPORT_SYMBOL_GPL(amd_nb_has_feature); + +struct amd_northbridge *node_to_amd_nb(int node) +{ + return (node < amd_northbridges.num) ? &amd_northbridges.nb[node] : NULL; +} +EXPORT_SYMBOL_GPL(node_to_amd_nb); static struct pci_dev *next_northbridge(struct pci_dev *dev, const struct pci_device_id *ids) @@ -58,13 +89,106 @@ static struct pci_dev *next_northbridge(struct pci_dev *dev, return dev; } +static int __amd_smn_rw(u16 node, u32 address, u32 *value, bool write) +{ + struct pci_dev *root; + int err = -ENODEV; + + if (node >= amd_northbridges.num) + goto out; + + root = node_to_amd_nb(node)->root; + if (!root) + goto out; + + mutex_lock(&smn_mutex); + + err = pci_write_config_dword(root, 0x60, address); + if (err) { + pr_warn("Error programming SMN address 0x%x.\n", address); + goto out_unlock; + } + + err = (write ? pci_write_config_dword(root, 0x64, *value) + : pci_read_config_dword(root, 0x64, value)); + if (err) + pr_warn("Error %s SMN address 0x%x.\n", + (write ? "writing to" : "reading from"), address); + +out_unlock: + mutex_unlock(&smn_mutex); + +out: + return err; +} + +int amd_smn_read(u16 node, u32 address, u32 *value) +{ + return __amd_smn_rw(node, address, value, false); +} +EXPORT_SYMBOL_GPL(amd_smn_read); + +int amd_smn_write(u16 node, u32 address, u32 value) +{ + return __amd_smn_rw(node, address, &value, true); +} +EXPORT_SYMBOL_GPL(amd_smn_write); + +/* + * Data Fabric Indirect Access uses FICAA/FICAD. + * + * Fabric Indirect Configuration Access Address (FICAA): Constructed based + * on the device's Instance Id and the PCI function and register offset of + * the desired register. + * + * Fabric Indirect Configuration Access Data (FICAD): There are FICAD LO + * and FICAD HI registers but so far we only need the LO register. + */ +int amd_df_indirect_read(u16 node, u8 func, u16 reg, u8 instance_id, u32 *lo) +{ + struct pci_dev *F4; + u32 ficaa; + int err = -ENODEV; + + if (node >= amd_northbridges.num) + goto out; + + F4 = node_to_amd_nb(node)->link; + if (!F4) + goto out; + + ficaa = 1; + ficaa |= reg & 0x3FC; + ficaa |= (func & 0x7) << 11; + ficaa |= instance_id << 16; + + mutex_lock(&smn_mutex); + + err = pci_write_config_dword(F4, 0x5C, ficaa); + if (err) { + pr_warn("Error writing DF Indirect FICAA, FICAA=0x%x\n", ficaa); + goto out_unlock; + } + + err = pci_read_config_dword(F4, 0x98, lo); + if (err) + pr_warn("Error reading DF Indirect FICAD LO, FICAA=0x%x.\n", ficaa); + +out_unlock: + mutex_unlock(&smn_mutex); + +out: + return err; +} +EXPORT_SYMBOL_GPL(amd_df_indirect_read); + int amd_cache_northbridges(void) { u16 i = 0; struct amd_northbridge *nb; - struct pci_dev *misc, *link; + struct pci_dev *root, *misc, *link; - if (amd_nb_num()) + if (amd_northbridges.num) return 0; misc = NULL; @@ -74,15 +198,17 @@ int amd_cache_northbridges(void) if (!i) return -ENODEV; - nb = kzalloc(i * sizeof(struct amd_northbridge), GFP_KERNEL); + nb = kcalloc(i, sizeof(struct amd_northbridge), GFP_KERNEL); if (!nb) return -ENOMEM; amd_northbridges.nb = nb; amd_northbridges.num = i; - link = misc = NULL; - for (i = 0; i != amd_nb_num(); i++) { + link = misc = root = NULL; + for (i = 0; i != amd_northbridges.num; i++) { + node_to_amd_nb(i)->root = root = + next_northbridge(root, amd_root_ids); node_to_amd_nb(i)->misc = misc = next_northbridge(misc, amd_nb_misc_ids); node_to_amd_nb(i)->link = link = @@ -139,13 +265,13 @@ struct resource *amd_get_mmconfig_range(struct resource *res) { u32 address; u64 base, msr; - unsigned segn_busn_bits; + unsigned int segn_busn_bits; if (boot_cpu_data.x86_vendor != X86_VENDOR_AMD) return NULL; /* assume all cpus from fam10h have mmconfig */ - if (boot_cpu_data.x86 < 0x10) + if (boot_cpu_data.x86 < 0x10) return NULL; address = MSR_FAM10H_MMIO_CONF_BASE; @@ -226,14 +352,14 @@ static void amd_cache_gart(void) if (!amd_nb_has_feature(AMD_NB_GART)) return; - flush_words = kmalloc(amd_nb_num() * sizeof(u32), GFP_KERNEL); + flush_words = kmalloc_array(amd_northbridges.num, sizeof(u32), GFP_KERNEL); if (!flush_words) { amd_northbridges.flags &= ~AMD_NB_GART; pr_notice("Cannot initialize GART flush words, GART support disabled\n"); return; } - for (i = 0; i != amd_nb_num(); i++) + for (i = 0; i != amd_northbridges.num; i++) pci_read_config_dword(node_to_amd_nb(i)->misc, 0x9c, &flush_words[i]); } @@ -246,18 +372,20 @@ void amd_flush_garts(void) if (!amd_nb_has_feature(AMD_NB_GART)) return; - /* Avoid races between AGP and IOMMU. In theory it's not needed - but I'm not sure if the hardware won't lose flush requests - when another is pending. This whole thing is so expensive anyways - that it doesn't matter to serialize more. -AK */ + /* + * Avoid races between AGP and IOMMU. In theory it's not needed + * but I'm not sure if the hardware won't lose flush requests + * when another is pending. This whole thing is so expensive anyways + * that it doesn't matter to serialize more. -AK + */ spin_lock_irqsave(&gart_lock, flags); flushed = 0; - for (i = 0; i < amd_nb_num(); i++) { + for (i = 0; i < amd_northbridges.num; i++) { pci_write_config_dword(node_to_amd_nb(i)->misc, 0x9c, flush_words[i] | 1); flushed++; } - for (i = 0; i < amd_nb_num(); i++) { + for (i = 0; i < amd_northbridges.num; i++) { u32 w; /* Make sure the hardware actually executed the flush*/ for (;;) { |