diff options
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/ABI/testing/sysfs-devices-power_resources_D0 | 13 | ||||
-rw-r--r-- | Documentation/ABI/testing/sysfs-devices-power_resources_D1 | 14 | ||||
-rw-r--r-- | Documentation/ABI/testing/sysfs-devices-power_resources_D2 | 14 | ||||
-rw-r--r-- | Documentation/ABI/testing/sysfs-devices-power_resources_D3hot | 14 | ||||
-rw-r--r-- | Documentation/ABI/testing/sysfs-devices-power_state | 20 | ||||
-rw-r--r-- | Documentation/ABI/testing/sysfs-devices-real_power_state | 23 | ||||
-rw-r--r-- | Documentation/ABI/testing/sysfs-devices-resource_in_use | 12 | ||||
-rw-r--r-- | Documentation/device-mapper/dm-raid.txt | 1 | ||||
-rw-r--r--[-rwxr-xr-x] | Documentation/hid/hid-sensor.txt | 0 | ||||
-rw-r--r-- | Documentation/kernel-parameters.txt | 2 | ||||
-rw-r--r-- | Documentation/x86/boot.txt | 27 | ||||
-rw-r--r-- | Documentation/x86/zero-page.txt | 4 |
12 files changed, 142 insertions, 2 deletions
diff --git a/Documentation/ABI/testing/sysfs-devices-power_resources_D0 b/Documentation/ABI/testing/sysfs-devices-power_resources_D0 new file mode 100644 index 000000000000..73b77a6be196 --- /dev/null +++ b/Documentation/ABI/testing/sysfs-devices-power_resources_D0 @@ -0,0 +1,13 @@ +What: /sys/devices/.../power_resources_D0/ +Date: January 2013 +Contact: Rafael J. Wysocki <rafael.j.wysocki@intel.com> +Description: + The /sys/devices/.../power_resources_D0/ directory is only + present for device objects representing ACPI device nodes that + use ACPI power resources for power management. + + If present, it contains symbolic links to device directories + representing ACPI power resources that need to be turned on for + the given device node to be in ACPI power state D0. The names + of the links are the same as the names of the directories they + point to. diff --git a/Documentation/ABI/testing/sysfs-devices-power_resources_D1 b/Documentation/ABI/testing/sysfs-devices-power_resources_D1 new file mode 100644 index 000000000000..30c20703fb8c --- /dev/null +++ b/Documentation/ABI/testing/sysfs-devices-power_resources_D1 @@ -0,0 +1,14 @@ +What: /sys/devices/.../power_resources_D1/ +Date: January 2013 +Contact: Rafael J. Wysocki <rafael.j.wysocki@intel.com> +Description: + The /sys/devices/.../power_resources_D1/ directory is only + present for device objects representing ACPI device nodes that + use ACPI power resources for power management and support ACPI + power state D1. + + If present, it contains symbolic links to device directories + representing ACPI power resources that need to be turned on for + the given device node to be in ACPI power state D1. The names + of the links are the same as the names of the directories they + point to. diff --git a/Documentation/ABI/testing/sysfs-devices-power_resources_D2 b/Documentation/ABI/testing/sysfs-devices-power_resources_D2 new file mode 100644 index 000000000000..fd9d84b421e1 --- /dev/null +++ b/Documentation/ABI/testing/sysfs-devices-power_resources_D2 @@ -0,0 +1,14 @@ +What: /sys/devices/.../power_resources_D2/ +Date: January 2013 +Contact: Rafael J. Wysocki <rafael.j.wysocki@intel.com> +Description: + The /sys/devices/.../power_resources_D2/ directory is only + present for device objects representing ACPI device nodes that + use ACPI power resources for power management and support ACPI + power state D2. + + If present, it contains symbolic links to device directories + representing ACPI power resources that need to be turned on for + the given device node to be in ACPI power state D2. The names + of the links are the same as the names of the directories they + point to. diff --git a/Documentation/ABI/testing/sysfs-devices-power_resources_D3hot b/Documentation/ABI/testing/sysfs-devices-power_resources_D3hot new file mode 100644 index 000000000000..3df32c20addf --- /dev/null +++ b/Documentation/ABI/testing/sysfs-devices-power_resources_D3hot @@ -0,0 +1,14 @@ +What: /sys/devices/.../power_resources_D3hot/ +Date: January 2013 +Contact: Rafael J. Wysocki <rafael.j.wysocki@intel.com> +Description: + The /sys/devices/.../power_resources_D3hot/ directory is only + present for device objects representing ACPI device nodes that + use ACPI power resources for power management and support ACPI + power state D3hot. + + If present, it contains symbolic links to device directories + representing ACPI power resources that need to be turned on for + the given device node to be in ACPI power state D3hot. The + names of the links are the same as the names of the directories + they point to. diff --git a/Documentation/ABI/testing/sysfs-devices-power_state b/Documentation/ABI/testing/sysfs-devices-power_state new file mode 100644 index 000000000000..7ad9546748f0 --- /dev/null +++ b/Documentation/ABI/testing/sysfs-devices-power_state @@ -0,0 +1,20 @@ +What: /sys/devices/.../power_state +Date: January 2013 +Contact: Rafael J. Wysocki <rafael.j.wysocki@intel.com> +Description: + The /sys/devices/.../power_state attribute is only present for + device objects representing ACPI device nodes that provide power + management methods. + + If present, it contains a string representing the current ACPI + power state of the given device node. Its possible values, + "D0", "D1", "D2", "D3hot", and "D3cold", reflect the power state + names defined by the ACPI specification (ACPI 4 and above). + + If the device node uses shared ACPI power resources, this state + determines a list of power resources required not to be turned + off. However, some power resources needed by the device node in + higher-power (lower-number) states may also be ON because of + some other devices using them at the moment. + + This attribute is read-only. diff --git a/Documentation/ABI/testing/sysfs-devices-real_power_state b/Documentation/ABI/testing/sysfs-devices-real_power_state new file mode 100644 index 000000000000..8b3527c82a7d --- /dev/null +++ b/Documentation/ABI/testing/sysfs-devices-real_power_state @@ -0,0 +1,23 @@ +What: /sys/devices/.../real_power_state +Date: January 2013 +Contact: Rafael J. Wysocki <rafael.j.wysocki@intel.com> +Description: + The /sys/devices/.../real_power_state attribute is only present + for device objects representing ACPI device nodes that provide + power management methods and use ACPI power resources for power + management. + + If present, it contains a string representing the real ACPI + power state of the given device node as returned by the _PSC + control method or inferred from the configuration of power + resources. Its possible values, "D0", "D1", "D2", "D3hot", and + "D3cold", reflect the power state names defined by the ACPI + specification (ACPI 4 and above). + + In some situations the value of this attribute may be different + from the value of the /sys/devices/.../power_state attribute for + the same device object. If that happens, some shared power + resources used by the device node are only ON because of some + other devices using them at the moment. + + This attribute is read-only. diff --git a/Documentation/ABI/testing/sysfs-devices-resource_in_use b/Documentation/ABI/testing/sysfs-devices-resource_in_use new file mode 100644 index 000000000000..b4a3bc5922a3 --- /dev/null +++ b/Documentation/ABI/testing/sysfs-devices-resource_in_use @@ -0,0 +1,12 @@ +What: /sys/devices/.../resource_in_use +Date: January 2013 +Contact: Rafael J. Wysocki <rafael.j.wysocki@intel.com> +Description: + The /sys/devices/.../resource_in_use attribute is only present + for device objects representing ACPI power resources. + + If present, it contains a number (0 or 1) representing the + current status of the given power resource (0 means that the + resource is not in use and therefore it has been turned off). + + This attribute is read-only. diff --git a/Documentation/device-mapper/dm-raid.txt b/Documentation/device-mapper/dm-raid.txt index 728c38c242d6..56fb62b09fc5 100644 --- a/Documentation/device-mapper/dm-raid.txt +++ b/Documentation/device-mapper/dm-raid.txt @@ -141,3 +141,4 @@ Version History 1.2.0 Handle creation of arrays that contain failed devices. 1.3.0 Added support for RAID 10 1.3.1 Allow device replacement/rebuild for RAID 10 +1.3.2 Fix/improve redundancy checking for RAID10 diff --git a/Documentation/hid/hid-sensor.txt b/Documentation/hid/hid-sensor.txt index 948b0989c433..948b0989c433 100755..100644 --- a/Documentation/hid/hid-sensor.txt +++ b/Documentation/hid/hid-sensor.txt diff --git a/Documentation/kernel-parameters.txt b/Documentation/kernel-parameters.txt index 363e348bff9b..6c723811c0a0 100644 --- a/Documentation/kernel-parameters.txt +++ b/Documentation/kernel-parameters.txt @@ -2438,7 +2438,7 @@ bytes respectively. Such letter suffixes can also be entirely omitted. real-time workloads. It can also improve energy efficiency for asymmetric multiprocessors. - rcu_nocbs_poll [KNL,BOOT] + rcu_nocb_poll [KNL,BOOT] Rather than requiring that offloaded CPUs (specified by rcu_nocbs= above) explicitly awaken the corresponding "rcuoN" kthreads, diff --git a/Documentation/x86/boot.txt b/Documentation/x86/boot.txt index 406d82d5d2bb..e540fd67f767 100644 --- a/Documentation/x86/boot.txt +++ b/Documentation/x86/boot.txt @@ -57,6 +57,10 @@ Protocol 2.10: (Kernel 2.6.31) Added a protocol for relaxed alignment Protocol 2.11: (Kernel 3.6) Added a field for offset of EFI handover protocol entry point. +Protocol 2.12: (Kernel 3.8) Added the xloadflags field and extension fields + to struct boot_params for for loading bzImage and ramdisk + above 4G in 64bit. + **** MEMORY LAYOUT The traditional memory map for the kernel loader, used for Image or @@ -182,7 +186,7 @@ Offset Proto Name Meaning 0230/4 2.05+ kernel_alignment Physical addr alignment required for kernel 0234/1 2.05+ relocatable_kernel Whether kernel is relocatable or not 0235/1 2.10+ min_alignment Minimum alignment, as a power of two -0236/2 N/A pad3 Unused +0236/2 2.12+ xloadflags Boot protocol option flags 0238/4 2.06+ cmdline_size Maximum size of the kernel command line 023C/4 2.07+ hardware_subarch Hardware subarchitecture 0240/8 2.07+ hardware_subarch_data Subarchitecture-specific data @@ -582,6 +586,27 @@ Protocol: 2.10+ misaligned kernel. Therefore, a loader should typically try each power-of-two alignment from kernel_alignment down to this alignment. +Field name: xloadflags +Type: read +Offset/size: 0x236/2 +Protocol: 2.12+ + + This field is a bitmask. + + Bit 0 (read): XLF_KERNEL_64 + - If 1, this kernel has the legacy 64-bit entry point at 0x200. + + Bit 1 (read): XLF_CAN_BE_LOADED_ABOVE_4G + - If 1, kernel/boot_params/cmdline/ramdisk can be above 4G. + + Bit 2 (read): XLF_EFI_HANDOVER_32 + - If 1, the kernel supports the 32-bit EFI handoff entry point + given at handover_offset. + + Bit 3 (read): XLF_EFI_HANDOVER_64 + - If 1, the kernel supports the 64-bit EFI handoff entry point + given at handover_offset + 0x200. + Field name: cmdline_size Type: read Offset/size: 0x238/4 diff --git a/Documentation/x86/zero-page.txt b/Documentation/x86/zero-page.txt index cf5437deda81..199f453cb4de 100644 --- a/Documentation/x86/zero-page.txt +++ b/Documentation/x86/zero-page.txt @@ -19,6 +19,9 @@ Offset Proto Name Meaning 090/010 ALL hd1_info hd1 disk parameter, OBSOLETE!! 0A0/010 ALL sys_desc_table System description table (struct sys_desc_table) 0B0/010 ALL olpc_ofw_header OLPC's OpenFirmware CIF and friends +0C0/004 ALL ext_ramdisk_image ramdisk_image high 32bits +0C4/004 ALL ext_ramdisk_size ramdisk_size high 32bits +0C8/004 ALL ext_cmd_line_ptr cmd_line_ptr high 32bits 140/080 ALL edid_info Video mode setup (struct edid_info) 1C0/020 ALL efi_info EFI 32 information (struct efi_info) 1E0/004 ALL alk_mem_k Alternative mem check, in KB @@ -27,6 +30,7 @@ Offset Proto Name Meaning 1E9/001 ALL eddbuf_entries Number of entries in eddbuf (below) 1EA/001 ALL edd_mbr_sig_buf_entries Number of entries in edd_mbr_sig_buffer (below) +1EF/001 ALL sentinel Used to detect broken bootloaders 290/040 ALL edd_mbr_sig_buffer EDD MBR signatures 2D0/A00 ALL e820_map E820 memory map table (array of struct e820entry) |