diff options
-rw-r--r-- | Documentation/devicetree/bindings/thermal/thermal.txt | 17 |
1 files changed, 9 insertions, 8 deletions
diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt index 8320186738ff..41b817f7b670 100644 --- a/Documentation/devicetree/bindings/thermal/thermal.txt +++ b/Documentation/devicetree/bindings/thermal/thermal.txt @@ -60,14 +60,6 @@ properties) should be defined in a particular device's binding. For more examples of cooling devices, refer to the example sections below. Required properties: -- cooling-min-level: An integer indicating the smallest - Type: unsigned cooling state accepted. Typically 0. - Size: one cell - -- cooling-max-level: An integer indicating the largest - Type: unsigned cooling state accepted. - Size: one cell - - #cooling-cells: Used to provide cooling device specific information Type: unsigned while referring to it. Must be at least 2, in order Size: one cell to specify minimum and maximum cooling state used @@ -77,6 +69,15 @@ Required properties: See Cooling device maps section below for more details on how consumers refer to cooling devices. +Optional properties: +- cooling-min-level: An integer indicating the smallest + Type: unsigned cooling state accepted. Typically 0. + Size: one cell + +- cooling-max-level: An integer indicating the largest + Type: unsigned cooling state accepted. + Size: one cell + * Trip points The trip node is a node to describe a point in the temperature domain |