summaryrefslogtreecommitdiff
path: root/include/linux/power_supply.h
diff options
context:
space:
mode:
authorRamakrishna Pallala <ramakrishna.pallala@intel.com>2012-05-06 16:46:44 +0400
committerAnton Vorontsov <cbouatmailru@gmail.com>2012-06-20 03:46:58 +0400
commit3824c47714f28091f74ca2505146514b4da1f390 (patch)
tree8d62fd09d62b75a90ce4bb67f13e698592229299 /include/linux/power_supply.h
parent3be330bf8860dc6079da5acc81295787a04cf4c9 (diff)
downloadlinux-3824c47714f28091f74ca2505146514b4da1f390.tar.xz
power_supply: Add constant charge_current and charge_voltage properties
Constant Charge Current(CC) is charging parameter which limit the maximum current which can be pumped into the battery during charge cycle. Constant Charge Voltage(CV) is also charging parameter which limit the maximum voltage that battery can reach during charge cycle. It is very common practice that at low or high temperatures we do not charge the batteries upto it's fullest charge voltage to avoid battery and user safety issues. These sysfs properties will be useful for debug and to implement certain user space policies like "Charging limited due to OverTemp". Signed-off-by: Ramakrishna Pallala <ramakrishna.pallala@intel.com> Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
Diffstat (limited to 'include/linux/power_supply.h')
-rw-r--r--include/linux/power_supply.h4
1 files changed, 4 insertions, 0 deletions
diff --git a/include/linux/power_supply.h b/include/linux/power_supply.h
index 59ed2dd9dba9..53f177db6ac9 100644
--- a/include/linux/power_supply.h
+++ b/include/linux/power_supply.h
@@ -109,6 +109,8 @@ enum power_supply_property {
POWER_SUPPLY_PROP_CHARGE_NOW,
POWER_SUPPLY_PROP_CHARGE_AVG,
POWER_SUPPLY_PROP_CHARGE_COUNTER,
+ POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT,
+ POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE,
POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN,
POWER_SUPPLY_PROP_ENERGY_EMPTY_DESIGN,
POWER_SUPPLY_PROP_ENERGY_FULL,
@@ -239,6 +241,7 @@ static inline bool power_supply_is_amp_property(enum power_supply_property psp)
case POWER_SUPPLY_PROP_CHARGE_NOW:
case POWER_SUPPLY_PROP_CHARGE_AVG:
case POWER_SUPPLY_PROP_CHARGE_COUNTER:
+ case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT:
case POWER_SUPPLY_PROP_CURRENT_MAX:
case POWER_SUPPLY_PROP_CURRENT_NOW:
case POWER_SUPPLY_PROP_CURRENT_AVG:
@@ -266,6 +269,7 @@ static inline bool power_supply_is_watt_property(enum power_supply_property psp)
case POWER_SUPPLY_PROP_VOLTAGE_NOW:
case POWER_SUPPLY_PROP_VOLTAGE_AVG:
case POWER_SUPPLY_PROP_VOLTAGE_OCV:
+ case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE:
case POWER_SUPPLY_PROP_POWER_NOW:
return 1;
default: