diff options
author | Chanwoo Choi <cw00.choi@samsung.com> | 2012-08-21 12:06:52 +0400 |
---|---|---|
committer | Anton Vorontsov <anton.vorontsov@linaro.org> | 2012-09-21 09:07:49 +0400 |
commit | 2ed9e9b6530951b5b96185e6761119361a166d7a (patch) | |
tree | dd5e298b0102b3dcb611be6710a2bed536c2741b /include/linux/power | |
parent | b9633ef1a9cdf4317d8c4a8db977485e2a8e1cb8 (diff) | |
download | linux-2ed9e9b6530951b5b96185e6761119361a166d7a.tar.xz |
charger-manager: Check fully charged state of battery periodically
This patch check periodically fully charged state of battery to protect
overcharge and overheat. If battery is fully charged, stop charging and
check droped voltage with 'fullbatt_vchkdrop_ms' period. When voltage of
battery is more droped than 'fullbatt_vchkdrop_uV' voltage,
charger-manager will restart charging for battery.
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
Diffstat (limited to 'include/linux/power')
-rw-r--r-- | include/linux/power/charger-manager.h | 8 |
1 files changed, 7 insertions, 1 deletions
diff --git a/include/linux/power/charger-manager.h b/include/linux/power/charger-manager.h index b542270affc1..76b37ef3c071 100644 --- a/include/linux/power/charger-manager.h +++ b/include/linux/power/charger-manager.h @@ -140,7 +140,11 @@ struct charger_regulator { * If it has dropped more than fullbatt_vchkdrop_uV after * fullbatt_vchkdrop_ms, CM will restart charging. * @fullbatt_uV: voltage in microvolt - * If it is not being charged and VBATT >= fullbatt_uV, + * If VBATT >= fullbatt_uV, it is assumed to be full. + * @fullbatt_soc: state of Charge in % + * If state of Charge >= fullbatt_soc, it is assumed to be full. + * @fullbatt_full_capacity: full capacity measure + * If full capacity of battery >= fullbatt_full_capacity, * it is assumed to be full. * @polling_interval_ms: interval in millisecond at which * charger manager will monitor battery health @@ -168,6 +172,8 @@ struct charger_desc { unsigned int fullbatt_vchkdrop_ms; unsigned int fullbatt_vchkdrop_uV; unsigned int fullbatt_uV; + unsigned int fullbatt_soc; + unsigned int fullbatt_full_capacity; enum data_source battery_present; |