diff options
author | Hans de Goede <hdegoede@redhat.com> | 2022-02-12 19:48:16 +0300 |
---|---|---|
committer | Sebastian Reichel <sre@kernel.org> | 2022-02-25 22:07:57 +0300 |
commit | f7731754fdce33dad19be746f647d6ac47c5d695 (patch) | |
tree | 8f0534aa12e1890480f854e3368b2cc027c1be97 /drivers/power | |
parent | da365db704d290fb4dc4cdbd41f60b0ecec1cc03 (diff) | |
download | linux-f7731754fdce33dad19be746f647d6ac47c5d695.tar.xz |
power: supply: bq24190_charger: Fix bq24190_vbus_is_enabled() wrong false return
The datasheet says that the BQ24190_REG_POC_CHG_CONFIG bits can
have a value of either 10(0x2) or 11(0x3) for OTG (5V boost regulator)
mode.
Sofar bq24190_vbus_is_enabled() was only checking for 10 but some BIOS-es
uses 11 when enabling the regulator at boot.
Make bq24190_vbus_is_enabled() also check for 11 so that it does not
wrongly returns false when the bits are set to 11.
Fixes: 66b6bef2c4e0 ("power: supply: bq24190_charger: Export 5V boost converter as regulator")
Cc: Bastien Nocera <hadess@hadess.net>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Diffstat (limited to 'drivers/power')
-rw-r--r-- | drivers/power/supply/bq24190_charger.c | 7 |
1 files changed, 6 insertions, 1 deletions
diff --git a/drivers/power/supply/bq24190_charger.c b/drivers/power/supply/bq24190_charger.c index 04aa25f2d033..dcbfd97a55be 100644 --- a/drivers/power/supply/bq24190_charger.c +++ b/drivers/power/supply/bq24190_charger.c @@ -39,6 +39,7 @@ #define BQ24190_REG_POC_CHG_CONFIG_DISABLE 0x0 #define BQ24190_REG_POC_CHG_CONFIG_CHARGE 0x1 #define BQ24190_REG_POC_CHG_CONFIG_OTG 0x2 +#define BQ24190_REG_POC_CHG_CONFIG_OTG_ALT 0x3 #define BQ24190_REG_POC_SYS_MIN_MASK (BIT(3) | BIT(2) | BIT(1)) #define BQ24190_REG_POC_SYS_MIN_SHIFT 1 #define BQ24190_REG_POC_SYS_MIN_MIN 3000 @@ -555,7 +556,11 @@ static int bq24190_vbus_is_enabled(struct regulator_dev *dev) pm_runtime_mark_last_busy(bdi->dev); pm_runtime_put_autosuspend(bdi->dev); - return ret ? ret : val == BQ24190_REG_POC_CHG_CONFIG_OTG; + if (ret) + return ret; + + return (val == BQ24190_REG_POC_CHG_CONFIG_OTG || + val == BQ24190_REG_POC_CHG_CONFIG_OTG_ALT); } static const struct regulator_ops bq24190_vbus_ops = { |