summaryrefslogtreecommitdiff
path: root/drivers/power
diff options
context:
space:
mode:
authorEvgeny Boger <boger@wirenboard.com>2022-01-12 11:47:27 +0300
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2022-04-15 15:15:01 +0300
commit81ad91d49821a17d7e0b0e08ba946550c464dc62 (patch)
tree78e7eb4188b7e323190b50d94d436f2c00246035 /drivers/power
parentfb723e5d6b012da7aae0c379eebff6a67f936907 (diff)
downloadlinux-81ad91d49821a17d7e0b0e08ba946550c464dc62.tar.xz
power: supply: axp20x_battery: properly report current when discharging
[ Upstream commit d4f408cdcd26921c1268cb8dcbe8ffb6faf837f3 ] As stated in [1], negative current values are used for discharging batteries. AXP PMICs internally have two different ADC channels for shunt current measurement: one used during charging and one during discharging. The values reported by these ADCs are unsigned. While the driver properly selects ADC channel to get the data from, it doesn't apply negative sign when reporting discharging current. [1] Documentation/ABI/testing/sysfs-class-power Signed-off-by: Evgeny Boger <boger@wirenboard.com> Acked-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com> Signed-off-by: Sasha Levin <sashal@kernel.org>
Diffstat (limited to 'drivers/power')
-rw-r--r--drivers/power/supply/axp20x_battery.c13
1 files changed, 6 insertions, 7 deletions
diff --git a/drivers/power/supply/axp20x_battery.c b/drivers/power/supply/axp20x_battery.c
index e84b6e4da14a..9fda98b950ba 100644
--- a/drivers/power/supply/axp20x_battery.c
+++ b/drivers/power/supply/axp20x_battery.c
@@ -185,7 +185,6 @@ static int axp20x_battery_get_prop(struct power_supply *psy,
union power_supply_propval *val)
{
struct axp20x_batt_ps *axp20x_batt = power_supply_get_drvdata(psy);
- struct iio_channel *chan;
int ret = 0, reg, val1;
switch (psp) {
@@ -265,12 +264,12 @@ static int axp20x_battery_get_prop(struct power_supply *psy,
if (ret)
return ret;
- if (reg & AXP20X_PWR_STATUS_BAT_CHARGING)
- chan = axp20x_batt->batt_chrg_i;
- else
- chan = axp20x_batt->batt_dischrg_i;
-
- ret = iio_read_channel_processed(chan, &val->intval);
+ if (reg & AXP20X_PWR_STATUS_BAT_CHARGING) {
+ ret = iio_read_channel_processed(axp20x_batt->batt_chrg_i, &val->intval);
+ } else {
+ ret = iio_read_channel_processed(axp20x_batt->batt_dischrg_i, &val1);
+ val->intval = -val1;
+ }
if (ret)
return ret;