power: supply: cpcap-charger: Fix charge voltage configuration
We have the charge voltage wrong, it should be 4.35V instead of 4.2V. This will cause the battery to never get fully charged. I noticed this when looking at the Andoid kernel battery and charger status for a fully charged battery: POWER_SUPPLY_VOLTAGE_NOW=4351000 Also the battery on droid 4 says "4.35, 1735/1785mAh (min/typ), 6.6/6.8 Wh (min/typ)". Presumably the 4.35 on the battery is the charge voltage. And finally, on Android the CPCAP CRM register is set to 0x03b5 where the b is the charge voltage. Let's fix the charge voltage define and update the charge configuration to use the 4.35V setting. Fixes: 0c9888e3c192 ("power: supply: cpcap-charger: Add minimal CPCAP PMIC battery charger") Cc: Marcel Partap <mpartap@gmx.net> Cc: Michael Scott <michael.scott@linaro.org> Signed-off-by: Tony Lindgren <tony@atomide.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
Diffstat (limited to 'drivers/power/supply')
-rw-r--r--drivers/power/supply/cpcap-charger.c4
1 files changed, 2 insertions, 2 deletions
diff --git a/drivers/power/supply/cpcap-charger.c b/drivers/power/supply/cpcap-charger.c
index 17907fcaebc3..33ca1174070b 100644
--- a/drivers/power/supply/cpcap-charger.c
+++ b/drivers/power/supply/cpcap-charger.c
@@ -76,7 +76,7 @@
#define CPCAP_REG_CRM_VCHRG_4V30 CPCAP_REG_CRM_VCHRG(0x8)
#define CPCAP_REG_CRM_VCHRG_4V32 CPCAP_REG_CRM_VCHRG(0x9)
#define CPCAP_REG_CRM_VCHRG_4V34 CPCAP_REG_CRM_VCHRG(0xa)
-#define CPCAP_REG_CRM_VCHRG_4V36 CPCAP_REG_CRM_VCHRG(0xb)
+#define CPCAP_REG_CRM_VCHRG_4V35 CPCAP_REG_CRM_VCHRG(0xb)
#define CPCAP_REG_CRM_VCHRG_4V38 CPCAP_REG_CRM_VCHRG(0xc)
#define CPCAP_REG_CRM_VCHRG_4V40 CPCAP_REG_CRM_VCHRG(0xd)
#define CPCAP_REG_CRM_VCHRG_4V42 CPCAP_REG_CRM_VCHRG(0xe)
@@ -433,7 +433,7 @@ static void cpcap_usb_detect(struct work_struct *work)
max_current = CPCAP_REG_CRM_ICHRG_0A528;
error = cpcap_charger_set_state(ddata,
- CPCAP_REG_CRM_VCHRG_4V20,
+ CPCAP_REG_CRM_VCHRG_4V35,
max_current,
CPCAP_REG_CRM_TR_0A72);
if (error)