author | Srikanth Krishnakar <skrishnakar@gmail.com> | 2019-09-20 12:31:56 +0300 |
---|---|---|
committer | Andy Shevchenko <andriy.shevchenko@linux.intel.com> | 2019-09-20 17:56:24 +0300 |
commit | f110d252ae7985def3cd0fd8b03979180a8633a0 (patch) | |
tree | 1c8a7cdfebdafcff75cedb489347fe93f6d0efc1 /drivers/platform | |
parent | b3abfd778bf1dbdd96f70bd7d00671d027f67c62 (diff) | |
download | linux-f110d252ae7985def3cd0fd8b03979180a8633a0.tar.xz |
platform/x86: pmc_atom: Add Siemens SIMATIC IPC277E to critclk_systems DMI table
The SIMATIC IPC277E uses the PMC clock for on-board components
and gets stuck during boot if the clock is disabled. Therefore,
add this device to the critical systems list.
Tested on SIMATIC IPC277E.
Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Reviewed-by: Jan Kiszka <jan.kiszka@siemens.com>
Cc: Cedric Hombourger <Cedric_Hombourger@mentor.com>
Signed-off-by: Srikanth Krishnakar <Srikanth_Krishnakar@mentor.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Diffstat (limited to 'drivers/platform')
-rw-r--r-- | drivers/platform/x86/pmc_atom.c | 7 |
1 files changed, 7 insertions, 0 deletions
diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c index 9aca5e7ce6d0..07d1b911e72f 100644 --- a/drivers/platform/x86/pmc_atom.c +++ b/drivers/platform/x86/pmc_atom.c @@ -422,6 +422,13 @@ static const struct dmi_system_id critclk_systems[] = { DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"), }, }, + { + .ident = "SIMATIC IPC277E", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"), + DMI_MATCH(DMI_PRODUCT_VERSION, "6AV7882-0"), + }, + }, { /*sentinel*/ } }; |