diff options
author | Neil Leeder <nleeder@codeaurora.org> | 2017-07-25 00:17:02 +0300 |
---|---|---|
committer | Will Deacon <will.deacon@arm.com> | 2017-07-26 11:27:43 +0300 |
commit | 6c17c1c3099d7367e67d51290884846dfeecf7bf (patch) | |
tree | 837f47c38e3fc99ecef48cac7a3df8067f286f4c /drivers/perf | |
parent | 288be97cc74e31b7871c75eb11a8dd768dcb535d (diff) | |
download | linux-6c17c1c3099d7367e67d51290884846dfeecf7bf.tar.xz |
perf: qcom_l2: fix column exclusion check
The check for column exclusion did not verify that the event being
checked was an L2 event, and not a software event.
Software events should not be checked for column exclusion.
This resulted in a group with both software and L2 events sometimes
incorrectly rejecting the L2 event for column exclusion and
not counting it.
Add a check for PMU type before applying column exclusion logic.
Fixes: 21bdbb7102edeaeb ("perf: add qcom l2 cache perf events driver")
Acked-by: Mark Rutland <mark.rutland@arm.com>
Signed-off-by: Neil Leeder <nleeder@codeaurora.org>
Signed-off-by: Will Deacon <will.deacon@arm.com>
Diffstat (limited to 'drivers/perf')
-rw-r--r-- | drivers/perf/qcom_l2_pmu.c | 2 |
1 files changed, 2 insertions, 0 deletions
diff --git a/drivers/perf/qcom_l2_pmu.c b/drivers/perf/qcom_l2_pmu.c index c259848228b4..b242cce10468 100644 --- a/drivers/perf/qcom_l2_pmu.c +++ b/drivers/perf/qcom_l2_pmu.c @@ -546,6 +546,7 @@ static int l2_cache_event_init(struct perf_event *event) } if ((event != event->group_leader) && + !is_software_event(event->group_leader) && (L2_EVT_GROUP(event->group_leader->attr.config) == L2_EVT_GROUP(event->attr.config))) { dev_dbg_ratelimited(&l2cache_pmu->pdev->dev, @@ -558,6 +559,7 @@ static int l2_cache_event_init(struct perf_event *event) list_for_each_entry(sibling, &event->group_leader->sibling_list, group_entry) { if ((sibling != event) && + !is_software_event(sibling) && (L2_EVT_GROUP(sibling->attr.config) == L2_EVT_GROUP(event->attr.config))) { dev_dbg_ratelimited(&l2cache_pmu->pdev->dev, |