diff options
author | Ming Lin <mlin@kernel.org> | 2016-04-12 22:10:14 +0300 |
---|---|---|
committer | Jens Axboe <axboe@fb.com> | 2016-04-12 22:44:00 +0300 |
commit | 8093f7ca73c1633e458c16a74b51bcc3c94564c4 (patch) | |
tree | a9a51fc5fc2d1f58343ff469b8e38d21b8525f51 /drivers/nvme | |
parent | 03b5929ebb20457e2fd13a701954efa2b2fb7ded (diff) | |
download | linux-8093f7ca73c1633e458c16a74b51bcc3c94564c4.tar.xz |
nvme: add helper nvme_setup_cmd()
This moves nvme_setup_{flush,discard,rw} calls into a common
nvme_setup_cmd() helper. So we can eventually hide all the command
setup in the core module and don't even need to update the fabrics
drivers for any specific command type.
Signed-off-by: Ming Lin <ming.l@ssi.samsung.com>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@fb.com>
Diffstat (limited to 'drivers/nvme')
-rw-r--r-- | drivers/nvme/host/core.c | 105 | ||||
-rw-r--r-- | drivers/nvme/host/nvme.h | 53 | ||||
-rw-r--r-- | drivers/nvme/host/pci.c | 47 |
3 files changed, 108 insertions, 97 deletions
diff --git a/drivers/nvme/host/core.c b/drivers/nvme/host/core.c index 643f457131c2..6631f38aebca 100644 --- a/drivers/nvme/host/core.c +++ b/drivers/nvme/host/core.c @@ -138,6 +138,111 @@ struct request *nvme_alloc_request(struct request_queue *q, } EXPORT_SYMBOL_GPL(nvme_alloc_request); +static inline void nvme_setup_flush(struct nvme_ns *ns, + struct nvme_command *cmnd) +{ + memset(cmnd, 0, sizeof(*cmnd)); + cmnd->common.opcode = nvme_cmd_flush; + cmnd->common.nsid = cpu_to_le32(ns->ns_id); +} + +static inline int nvme_setup_discard(struct nvme_ns *ns, struct request *req, + struct nvme_command *cmnd) +{ + struct nvme_dsm_range *range; + struct page *page; + int offset; + unsigned int nr_bytes = blk_rq_bytes(req); + + range = kmalloc(sizeof(*range), GFP_ATOMIC); + if (!range) + return BLK_MQ_RQ_QUEUE_BUSY; + + range->cattr = cpu_to_le32(0); + range->nlb = cpu_to_le32(nr_bytes >> ns->lba_shift); + range->slba = cpu_to_le64(nvme_block_nr(ns, blk_rq_pos(req))); + + memset(cmnd, 0, sizeof(*cmnd)); + cmnd->dsm.opcode = nvme_cmd_dsm; + cmnd->dsm.nsid = cpu_to_le32(ns->ns_id); + cmnd->dsm.nr = 0; + cmnd->dsm.attributes = cpu_to_le32(NVME_DSMGMT_AD); + + req->completion_data = range; + page = virt_to_page(range); + offset = offset_in_page(range); + blk_add_request_payload(req, page, offset, sizeof(*range)); + + /* + * we set __data_len back to the size of the area to be discarded + * on disk. This allows us to report completion on the full amount + * of blocks described by the request. + */ + req->__data_len = nr_bytes; + + return 0; +} + +static inline void nvme_setup_rw(struct nvme_ns *ns, struct request *req, + struct nvme_command *cmnd) +{ + u16 control = 0; + u32 dsmgmt = 0; + + if (req->cmd_flags & REQ_FUA) + control |= NVME_RW_FUA; + if (req->cmd_flags & (REQ_FAILFAST_DEV | REQ_RAHEAD)) + control |= NVME_RW_LR; + + if (req->cmd_flags & REQ_RAHEAD) + dsmgmt |= NVME_RW_DSM_FREQ_PREFETCH; + + memset(cmnd, 0, sizeof(*cmnd)); + cmnd->rw.opcode = (rq_data_dir(req) ? nvme_cmd_write : nvme_cmd_read); + cmnd->rw.command_id = req->tag; + cmnd->rw.nsid = cpu_to_le32(ns->ns_id); + cmnd->rw.slba = cpu_to_le64(nvme_block_nr(ns, blk_rq_pos(req))); + cmnd->rw.length = cpu_to_le16((blk_rq_bytes(req) >> ns->lba_shift) - 1); + + if (ns->ms) { + switch (ns->pi_type) { + case NVME_NS_DPS_PI_TYPE3: + control |= NVME_RW_PRINFO_PRCHK_GUARD; + break; + case NVME_NS_DPS_PI_TYPE1: + case NVME_NS_DPS_PI_TYPE2: + control |= NVME_RW_PRINFO_PRCHK_GUARD | + NVME_RW_PRINFO_PRCHK_REF; + cmnd->rw.reftag = cpu_to_le32( + nvme_block_nr(ns, blk_rq_pos(req))); + break; + } + if (!blk_integrity_rq(req)) + control |= NVME_RW_PRINFO_PRACT; + } + + cmnd->rw.control = cpu_to_le16(control); + cmnd->rw.dsmgmt = cpu_to_le32(dsmgmt); +} + +int nvme_setup_cmd(struct nvme_ns *ns, struct request *req, + struct nvme_command *cmd) +{ + int ret = 0; + + if (req->cmd_type == REQ_TYPE_DRV_PRIV) + memcpy(cmd, req->cmd, sizeof(*cmd)); + else if (req->cmd_flags & REQ_FLUSH) + nvme_setup_flush(ns, cmd); + else if (req->cmd_flags & REQ_DISCARD) + ret = nvme_setup_discard(ns, req, cmd); + else + nvme_setup_rw(ns, req, cmd); + + return ret; +} +EXPORT_SYMBOL_GPL(nvme_setup_cmd); + /* * Returns 0 on success. If the result is negative, it's a Linux error code; * if the result is positive, it's an NVM Express status code diff --git a/drivers/nvme/host/nvme.h b/drivers/nvme/host/nvme.h index 6376cd71cc9f..8e8fae8722f8 100644 --- a/drivers/nvme/host/nvme.h +++ b/drivers/nvme/host/nvme.h @@ -181,57 +181,6 @@ static inline unsigned nvme_map_len(struct request *rq) return blk_rq_bytes(rq); } -static inline void nvme_setup_flush(struct nvme_ns *ns, - struct nvme_command *cmnd) -{ - memset(cmnd, 0, sizeof(*cmnd)); - cmnd->common.opcode = nvme_cmd_flush; - cmnd->common.nsid = cpu_to_le32(ns->ns_id); -} - -static inline void nvme_setup_rw(struct nvme_ns *ns, struct request *req, - struct nvme_command *cmnd) -{ - u16 control = 0; - u32 dsmgmt = 0; - - if (req->cmd_flags & REQ_FUA) - control |= NVME_RW_FUA; - if (req->cmd_flags & (REQ_FAILFAST_DEV | REQ_RAHEAD)) - control |= NVME_RW_LR; - - if (req->cmd_flags & REQ_RAHEAD) - dsmgmt |= NVME_RW_DSM_FREQ_PREFETCH; - - memset(cmnd, 0, sizeof(*cmnd)); - cmnd->rw.opcode = (rq_data_dir(req) ? nvme_cmd_write : nvme_cmd_read); - cmnd->rw.command_id = req->tag; - cmnd->rw.nsid = cpu_to_le32(ns->ns_id); - cmnd->rw.slba = cpu_to_le64(nvme_block_nr(ns, blk_rq_pos(req))); - cmnd->rw.length = cpu_to_le16((blk_rq_bytes(req) >> ns->lba_shift) - 1); - - if (ns->ms) { - switch (ns->pi_type) { - case NVME_NS_DPS_PI_TYPE3: - control |= NVME_RW_PRINFO_PRCHK_GUARD; - break; - case NVME_NS_DPS_PI_TYPE1: - case NVME_NS_DPS_PI_TYPE2: - control |= NVME_RW_PRINFO_PRCHK_GUARD | - NVME_RW_PRINFO_PRCHK_REF; - cmnd->rw.reftag = cpu_to_le32( - nvme_block_nr(ns, blk_rq_pos(req))); - break; - } - if (!blk_integrity_rq(req)) - control |= NVME_RW_PRINFO_PRACT; - } - - cmnd->rw.control = cpu_to_le16(control); - cmnd->rw.dsmgmt = cpu_to_le32(dsmgmt); -} - - static inline int nvme_error_status(u16 status) { switch (status & 0x7ff) { @@ -269,6 +218,8 @@ void nvme_kill_queues(struct nvme_ctrl *ctrl); struct request *nvme_alloc_request(struct request_queue *q, struct nvme_command *cmd, unsigned int flags); void nvme_requeue_req(struct request *req); +int nvme_setup_cmd(struct nvme_ns *ns, struct request *req, + struct nvme_command *cmd); int nvme_submit_sync_cmd(struct request_queue *q, struct nvme_command *cmd, void *buf, unsigned bufflen); int __nvme_submit_sync_cmd(struct request_queue *q, struct nvme_command *cmd, diff --git a/drivers/nvme/host/pci.c b/drivers/nvme/host/pci.c index 0bf7f61a0a89..008c9eec437a 100644 --- a/drivers/nvme/host/pci.c +++ b/drivers/nvme/host/pci.c @@ -593,43 +593,6 @@ static void nvme_unmap_data(struct nvme_dev *dev, struct request *req) nvme_free_iod(dev, req); } -static inline int nvme_setup_discard(struct nvme_ns *ns, struct request *req, - struct nvme_command *cmnd) -{ - struct nvme_dsm_range *range; - struct page *page; - int offset; - unsigned int nr_bytes = blk_rq_bytes(req); - - range = kmalloc(sizeof(*range), GFP_ATOMIC); - if (!range) - return BLK_MQ_RQ_QUEUE_BUSY; - - range->cattr = cpu_to_le32(0); - range->nlb = cpu_to_le32(nr_bytes >> ns->lba_shift); - range->slba = cpu_to_le64(nvme_block_nr(ns, blk_rq_pos(req))); - - memset(cmnd, 0, sizeof(*cmnd)); - cmnd->dsm.opcode = nvme_cmd_dsm; - cmnd->dsm.nsid = cpu_to_le32(ns->ns_id); - cmnd->dsm.nr = 0; - cmnd->dsm.attributes = cpu_to_le32(NVME_DSMGMT_AD); - - req->completion_data = range; - page = virt_to_page(range); - offset = offset_in_page(range); - blk_add_request_payload(req, page, offset, sizeof(*range)); - - /* - * we set __data_len back to the size of the area to be discarded - * on disk. This allows us to report completion on the full amount - * of blocks described by the request. - */ - req->__data_len = nr_bytes; - - return 0; -} - /* * NOTE: ns is NULL when called on the admin queue. */ @@ -662,15 +625,7 @@ static int nvme_queue_rq(struct blk_mq_hw_ctx *hctx, if (ret) return ret; - if (req->cmd_type == REQ_TYPE_DRV_PRIV) - memcpy(&cmnd, req->cmd, sizeof(cmnd)); - else if (req->cmd_flags & REQ_FLUSH) - nvme_setup_flush(ns, &cmnd); - else if (req->cmd_flags & REQ_DISCARD) - ret = nvme_setup_discard(ns, req, &cmnd); - else - nvme_setup_rw(ns, req, &cmnd); - + ret = nvme_setup_cmd(ns, req, &cmnd); if (ret) goto out; |