diff options
author | Jeremy Linton <jeremy.linton@arm.com> | 2020-06-22 18:05:32 +0300 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2020-06-24 06:35:15 +0300 |
commit | 0cc8fecf041d3e5285380da62cc6662bdc942d8c (patch) | |
tree | 6976c1fadad4d6bde98e126787916ad2c15cb058 /drivers/net/phy/mdio_bus.c | |
parent | 1c59bb6bcbe88aff1527e8eae396d5d5a706e659 (diff) | |
download | linux-0cc8fecf041d3e5285380da62cc6662bdc942d8c.tar.xz |
net: phy: Allow mdio buses to auto-probe c45 devices
The mdiobus_scan logic is currently hardcoded to only
work with c22 devices. This works fairly well in most
cases, but its possible that a c45 device doesn't respond
despite being a standard phy. If the parent hardware
is capable, it makes sense to scan for c22 devices before
falling back to c45.
As we want this to reflect the capabilities of the STA,
lets add a field to the mii_bus structure to represent
the capability. That way devices can opt into the extended
scanning. Existing users should continue to default to c22
only scanning as long as they are zero'ing the structure
before use.
Signed-off-by: Jeremy Linton <jeremy.linton@arm.com>
Signed-off-by: Calvin Johnson <calvin.johnson@oss.nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/phy/mdio_bus.c')
-rw-r--r-- | drivers/net/phy/mdio_bus.c | 18 |
1 files changed, 16 insertions, 2 deletions
diff --git a/drivers/net/phy/mdio_bus.c b/drivers/net/phy/mdio_bus.c index 6ceee82b2839..ab9233c558d8 100644 --- a/drivers/net/phy/mdio_bus.c +++ b/drivers/net/phy/mdio_bus.c @@ -739,10 +739,24 @@ EXPORT_SYMBOL(mdiobus_free); */ struct phy_device *mdiobus_scan(struct mii_bus *bus, int addr) { - struct phy_device *phydev; + struct phy_device *phydev = ERR_PTR(-ENODEV); int err; - phydev = get_phy_device(bus, addr, false); + switch (bus->probe_capabilities) { + case MDIOBUS_NO_CAP: + case MDIOBUS_C22: + phydev = get_phy_device(bus, addr, false); + break; + case MDIOBUS_C45: + phydev = get_phy_device(bus, addr, true); + break; + case MDIOBUS_C22_C45: + phydev = get_phy_device(bus, addr, false); + if (IS_ERR(phydev)) + phydev = get_phy_device(bus, addr, true); + break; + } + if (IS_ERR(phydev)) return phydev; |