summaryrefslogtreecommitdiff
path: root/drivers/net/ethernet/intel
diff options
context:
space:
mode:
authorMiroslav Lichvar <mlichvar@redhat.com>2018-10-12 14:13:39 +0300
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2019-12-01 11:13:58 +0300
commit8bcacb4e6959d22ca9f54d260e0edcfec9265bac (patch)
tree554f89571798d28421454200fc668731d4d89613 /drivers/net/ethernet/intel
parent5cb8388a680a363ba9a8cca8f81687f9b0d238bb (diff)
downloadlinux-8bcacb4e6959d22ca9f54d260e0edcfec9265bac.tar.xz
igb: shorten maximum PHC timecounter update interval
[ Upstream commit 094bf4d0e9657f6ea1ee3d7e07ce3970796949ce ] The timecounter needs to be updated at least once per ~550 seconds in order to avoid a 40-bit SYSTIM timestamp to be misinterpreted as an old timestamp. Since commit 500462a9d ("timers: Switch to a non-cascading wheel"), scheduling of delayed work seems to be less accurate and a requested delay of 540 seconds may actually be longer than 550 seconds. Shorten the delay to 480 seconds to be sure the timecounter is updated in time. This fixes an issue with HW timestamps on 82580/I350/I354 being off by ~1100 seconds for few seconds every ~9 minutes. Cc: Jacob Keller <jacob.e.keller@intel.com> Cc: Richard Cochran <richardcochran@gmail.com> Cc: Thomas Gleixner <tglx@linutronix.de> Signed-off-by: Miroslav Lichvar <mlichvar@redhat.com> Tested-by: Aaron Brown <aaron.f.brown@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com> Signed-off-by: Sasha Levin <sashal@kernel.org>
Diffstat (limited to 'drivers/net/ethernet/intel')
-rw-r--r--drivers/net/ethernet/intel/igb/igb_ptp.c8
1 files changed, 7 insertions, 1 deletions
diff --git a/drivers/net/ethernet/intel/igb/igb_ptp.c b/drivers/net/ethernet/intel/igb/igb_ptp.c
index 0746b19ec6d3..295d27f33104 100644
--- a/drivers/net/ethernet/intel/igb/igb_ptp.c
+++ b/drivers/net/ethernet/intel/igb/igb_ptp.c
@@ -65,9 +65,15 @@
*
* The 40 bit 82580 SYSTIM overflows every
* 2^40 * 10^-9 / 60 = 18.3 minutes.
+ *
+ * SYSTIM is converted to real time using a timecounter. As
+ * timecounter_cyc2time() allows old timestamps, the timecounter
+ * needs to be updated at least once per half of the SYSTIM interval.
+ * Scheduling of delayed work is not very accurate, so we aim for 8
+ * minutes to be sure the actual interval is shorter than 9.16 minutes.
*/
-#define IGB_SYSTIM_OVERFLOW_PERIOD (HZ * 60 * 9)
+#define IGB_SYSTIM_OVERFLOW_PERIOD (HZ * 60 * 8)
#define IGB_PTP_TX_TIMEOUT (HZ * 15)
#define INCPERIOD_82576 BIT(E1000_TIMINCA_16NS_SHIFT)
#define INCVALUE_82576_MASK GENMASK(E1000_TIMINCA_16NS_SHIFT - 1, 0)