authorMike Looijmans <mike.looijmans@topic.nl>2019-03-06 10:31:47 +0300
committerJonathan Cameron <Jonathan.Cameron@huawei.com>2019-03-09 20:27:12 +0300
commit9436f45dd53595e21566a8c6627411077dfdb776 (patch)
tree81d52fd28dc2378dcf38d5bc389fdaa1f8155740 /drivers/iio
parent831d2fefdfce757fcea86742220f8cbe7ca51ddd (diff)
downloadlinux-9436f45dd53595e21566a8c6627411077dfdb776.tar.xz
iio:chemical:bme680: Fix, report temperature in millidegrees
The standard unit for temperature is millidegrees Celcius. Adapt the driver to report in millidegrees instead of degrees. Signed-off-by: Mike Looijmans <mike.looijmans@topic.nl> Fixes: 1b3bd8592780 ("iio: chemical: Add support for Bosch BME680 sensor"); Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Diffstat (limited to 'drivers/iio')
-rw-r--r--drivers/iio/chemical/bme680_core.c16
1 files changed, 7 insertions, 9 deletions
diff --git a/drivers/iio/chemical/bme680_core.c b/drivers/iio/chemical/bme680_core.c
index 70c1fe4366f4..fefe32b5b69d 100644
--- a/drivers/iio/chemical/bme680_core.c
+++ b/drivers/iio/chemical/bme680_core.c
@@ -583,8 +583,7 @@ static int bme680_gas_config(struct bme680_data *data)
return ret;
}
-static int bme680_read_temp(struct bme680_data *data,
- int *val, int *val2)
+static int bme680_read_temp(struct bme680_data *data, int *val)
{
struct device *dev = regmap_get_device(data->regmap);
int ret;
@@ -617,10 +616,9 @@ static int bme680_read_temp(struct bme680_data *data,
* compensate_press/compensate_humid to get compensated
* pressure/humidity readings.
*/
- if (val && val2) {
- *val = comp_temp;
- *val2 = 100;
- return IIO_VAL_FRACTIONAL;
+ if (val) {
+ *val = comp_temp * 10; /* Centidegrees to millidegrees */
+ return IIO_VAL_INT;
}
return ret;
@@ -635,7 +633,7 @@ static int bme680_read_press(struct bme680_data *data,
s32 adc_press;
/* Read and compensate temperature to get a reading of t_fine */
- ret = bme680_read_temp(data, NULL, NULL);
+ ret = bme680_read_temp(data, NULL);
if (ret < 0)
return ret;
@@ -668,7 +666,7 @@ static int bme680_read_humid(struct bme680_data *data,
u32 comp_humidity;
/* Read and compensate temperature to get a reading of t_fine */
- ret = bme680_read_temp(data, NULL, NULL);
+ ret = bme680_read_temp(data, NULL);
if (ret < 0)
return ret;
@@ -761,7 +759,7 @@ static int bme680_read_raw(struct iio_dev *indio_dev,
case IIO_CHAN_INFO_PROCESSED:
switch (chan->type) {
case IIO_TEMP:
- return bme680_read_temp(data, val, val2);
+ return bme680_read_temp(data, val);
case IIO_PRESSURE:
return bme680_read_press(data, val, val2);
case IIO_HUMIDITYRELATIVE: