diff options
author | Philipp Jungkamp <p.jungkamp@gmx.net> | 2022-11-25 02:38:40 +0300 |
---|---|---|
committer | Jiri Kosina <jkosina@suse.cz> | 2022-12-20 17:24:57 +0300 |
commit | 3a04a1862d9b130fce24553e93db681dc311a29e (patch) | |
tree | e9629330225cfb17f03c49bc65b87bddd617613e /drivers/iio/light | |
parent | 48c79bb0abc0429751c0de6616224f8e4aa891cf (diff) | |
download | linux-3a04a1862d9b130fce24553e93db681dc311a29e.tar.xz |
IIO: hid-sensor-als: Use generic usage
Use a generic 'hsdev->usage' instead of the HID_USAGE_SENSOR_ALS to
allow this driver to drive the Lenovo custom ambient light sensor,
which is registered under a 'custom' usage and not HID_USAGE_SENSOR_ALS.
Add the Lenovo Intelligent Sensing Solution (LISS) ambient light sensor
to the platform device ids.
Signed-off-by: Philipp Jungkamp <p.jungkamp@gmx.net>
Reviewed-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Diffstat (limited to 'drivers/iio/light')
-rw-r--r-- | drivers/iio/light/hid-sensor-als.c | 27 |
1 files changed, 14 insertions, 13 deletions
diff --git a/drivers/iio/light/hid-sensor-als.c b/drivers/iio/light/hid-sensor-als.c index 5a1a625d8d16..eb1aedad7edc 100644 --- a/drivers/iio/light/hid-sensor-als.c +++ b/drivers/iio/light/hid-sensor-als.c @@ -86,6 +86,7 @@ static int als_read_raw(struct iio_dev *indio_dev, long mask) { struct als_state *als_state = iio_priv(indio_dev); + struct hid_sensor_hub_device *hsdev = als_state->common_attributes.hsdev; int report_id = -1; u32 address; int ret_type; @@ -110,11 +111,8 @@ static int als_read_raw(struct iio_dev *indio_dev, hid_sensor_power_state(&als_state->common_attributes, true); *val = sensor_hub_input_attr_get_raw_value( - als_state->common_attributes.hsdev, - HID_USAGE_SENSOR_ALS, address, - report_id, - SENSOR_HUB_SYNC, - min < 0); + hsdev, hsdev->usage, address, report_id, + SENSOR_HUB_SYNC, min < 0); hid_sensor_power_state(&als_state->common_attributes, false); } else { @@ -259,9 +257,7 @@ static int als_parse_report(struct platform_device *pdev, dev_dbg(&pdev->dev, "als %x:%x\n", st->als_illum.index, st->als_illum.report_id); - st->scale_precision = hid_sensor_format_scale( - HID_USAGE_SENSOR_ALS, - &st->als_illum, + st->scale_precision = hid_sensor_format_scale(usage_id, &st->als_illum, &st->scale_pre_decml, &st->scale_post_decml); return ret; @@ -285,7 +281,8 @@ static int hid_als_probe(struct platform_device *pdev) als_state->common_attributes.hsdev = hsdev; als_state->common_attributes.pdev = pdev; - ret = hid_sensor_parse_common_attributes(hsdev, HID_USAGE_SENSOR_ALS, + ret = hid_sensor_parse_common_attributes(hsdev, + hsdev->usage, &als_state->common_attributes, als_sensitivity_addresses, ARRAY_SIZE(als_sensitivity_addresses)); @@ -303,7 +300,8 @@ static int hid_als_probe(struct platform_device *pdev) ret = als_parse_report(pdev, hsdev, (struct iio_chan_spec *)indio_dev->channels, - HID_USAGE_SENSOR_ALS, als_state); + hsdev->usage, + als_state); if (ret) { dev_err(&pdev->dev, "failed to setup attributes\n"); return ret; @@ -333,8 +331,7 @@ static int hid_als_probe(struct platform_device *pdev) als_state->callbacks.send_event = als_proc_event; als_state->callbacks.capture_sample = als_capture_sample; als_state->callbacks.pdev = pdev; - ret = sensor_hub_register_callback(hsdev, HID_USAGE_SENSOR_ALS, - &als_state->callbacks); + ret = sensor_hub_register_callback(hsdev, hsdev->usage, &als_state->callbacks); if (ret < 0) { dev_err(&pdev->dev, "callback reg failed\n"); goto error_iio_unreg; @@ -356,7 +353,7 @@ static int hid_als_remove(struct platform_device *pdev) struct iio_dev *indio_dev = platform_get_drvdata(pdev); struct als_state *als_state = iio_priv(indio_dev); - sensor_hub_remove_callback(hsdev, HID_USAGE_SENSOR_ALS); + sensor_hub_remove_callback(hsdev, hsdev->usage); iio_device_unregister(indio_dev); hid_sensor_remove_trigger(indio_dev, &als_state->common_attributes); @@ -368,6 +365,10 @@ static const struct platform_device_id hid_als_ids[] = { /* Format: HID-SENSOR-usage_id_in_hex_lowercase */ .name = "HID-SENSOR-200041", }, + { + /* Format: HID-SENSOR-custom_sensor_tag-usage_id_in_hex_lowercase */ + .name = "HID-SENSOR-LISS-0041", + }, { /* sentinel */ } }; MODULE_DEVICE_TABLE(platform, hid_als_ids); |