diff options
author | Aleksa Savic <savicaleksa83@gmail.com> | 2022-09-07 13:07:39 +0300 |
---|---|---|
committer | Guenter Roeck <linux@roeck-us.net> | 2022-09-19 16:17:06 +0300 |
commit | aed80bb91de89d1d484f659056d740047c54e065 (patch) | |
tree | 495860ba5179cbf405b716692ff1964624079489 /drivers/hwmon/aquacomputer_d5next.c | |
parent | 856361b397439157f7f60fd21efb522bb11f537a (diff) | |
download | linux-aed80bb91de89d1d484f659056d740047c54e065.tar.xz |
hwmon: (aquacomputer_d5next) Add support for Aquacomputer High Flow Next
Extend aquacomputer_d5next driver to expose various hardware
sensors of the Aquacomputer High Flow Next flow sensor, which
communicates through a proprietary USB HID protocol.
The High Flow Next exposes +5V voltages, water quality, conductivity
and flow readings. A temperature sensor can be connected to it, in
which case it provides its reading and an estimation of the
dissipated/absorbed power in the liquid cooling loop.
Additionally, serial number and firmware version are exposed through
debugfs.
Registry offsets were discovered and tested by users on Github [1] [2].
[1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/issues/8
[2] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/34
Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
Link: https://lore.kernel.org/r/20220907100739.806571-1-savicaleksa83@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'drivers/hwmon/aquacomputer_d5next.c')
-rw-r--r-- | drivers/hwmon/aquacomputer_d5next.c | 91 |
1 files changed, 88 insertions, 3 deletions
diff --git a/drivers/hwmon/aquacomputer_d5next.c b/drivers/hwmon/aquacomputer_d5next.c index 77cc8f50b8af..c51a2678f0eb 100644 --- a/drivers/hwmon/aquacomputer_d5next.c +++ b/drivers/hwmon/aquacomputer_d5next.c @@ -1,7 +1,7 @@ // SPDX-License-Identifier: GPL-2.0+ /* * hwmon driver for Aquacomputer devices (D5 Next, Farbwerk, Farbwerk 360, Octo, - * Quadro) + * Quadro, High Flow Next) * * Aquacomputer devices send HID reports (with ID 0x01) every second to report * sensor values. @@ -26,15 +26,17 @@ #define USB_PRODUCT_ID_D5NEXT 0xf00e #define USB_PRODUCT_ID_FARBWERK360 0xf010 #define USB_PRODUCT_ID_OCTO 0xf011 +#define USB_PRODUCT_ID_HIGHFLOWNEXT 0xf012 -enum kinds { d5next, farbwerk, farbwerk360, octo, quadro }; +enum kinds { d5next, farbwerk, farbwerk360, octo, quadro, highflownext }; static const char *const aqc_device_names[] = { [d5next] = "d5next", [farbwerk] = "farbwerk", [farbwerk360] = "farbwerk360", [octo] = "octo", - [quadro] = "quadro" + [quadro] = "quadro", + [highflownext] = "highflownext" }; #define DRIVER_NAME "aquacomputer_d5next" @@ -120,6 +122,16 @@ static u8 quadro_sensor_fan_offsets[] = { 0x70, 0x7D, 0x8A, 0x97 }; /* Fan speed registers in Quadro control report (from 0-100%) */ static u16 quadro_ctrl_fan_offsets[] = { 0x37, 0x8c, 0xe1, 0x136 }; +/* Register offsets for the High Flow Next */ +#define HIGHFLOWNEXT_NUM_SENSORS 2 +#define HIGHFLOWNEXT_SENSOR_START 85 +#define HIGHFLOWNEXT_FLOW 81 +#define HIGHFLOWNEXT_WATER_QUALITY 89 +#define HIGHFLOWNEXT_POWER 91 +#define HIGHFLOWNEXT_CONDUCTIVITY 95 +#define HIGHFLOWNEXT_5V_VOLTAGE 97 +#define HIGHFLOWNEXT_5V_VOLTAGE_USB 99 + /* Labels for D5 Next */ static const char *const label_d5next_temp[] = { "Coolant temp" @@ -228,6 +240,27 @@ static const char *const label_quadro_speeds[] = { "Flow speed [dL/h]" }; +/* Labels for High Flow Next */ +static const char *const label_highflownext_temp_sensors[] = { + "Coolant temp", + "External sensor" +}; + +static const char *const label_highflownext_fan_speed[] = { + "Flow [dL/h]", + "Water quality [%]", + "Conductivity [nS/cm]", +}; + +static const char *const label_highflownext_power[] = { + "Dissipated power", +}; + +static const char *const label_highflownext_voltage[] = { + "+5V voltage", + "+5V USB voltage" +}; + struct aqc_data { struct hid_device *hdev; struct device *hwmon_dev; @@ -390,6 +423,11 @@ static umode_t aqc_is_visible(const void *data, enum hwmon_sensor_types type, u3 break; case hwmon_fan: switch (priv->kind) { + case highflownext: + /* Special case to support flow sensor, water quality and conductivity */ + if (channel < 3) + return 0444; + break; case quadro: /* Special case to support flow sensor */ if (channel < priv->num_fans + 1) @@ -402,6 +440,18 @@ static umode_t aqc_is_visible(const void *data, enum hwmon_sensor_types type, u3 } break; case hwmon_power: + switch (priv->kind) { + case highflownext: + /* Special case to support one power sensor */ + if (channel == 0) + return 0444; + break; + default: + if (channel < priv->num_fans) + return 0444; + break; + } + break; case hwmon_curr: if (channel < priv->num_fans) return 0444; @@ -413,6 +463,11 @@ static umode_t aqc_is_visible(const void *data, enum hwmon_sensor_types type, u3 if (channel < priv->num_fans + 2) return 0444; break; + case highflownext: + /* Special case to support two voltage sensors */ + if (channel < 2) + return 0444; + break; default: if (channel < priv->num_fans) return 0444; @@ -679,6 +734,22 @@ static int aqc_raw_event(struct hid_device *hdev, struct hid_report *report, u8 case quadro: priv->speed_input[4] = get_unaligned_be16(data + priv->flow_sensor_offset); break; + case highflownext: + /* If external temp sensor is not connected, its power reading is also N/A */ + if (priv->temp_input[1] == -ENODATA) + priv->power_input[0] = -ENODATA; + else + priv->power_input[0] = + get_unaligned_be16(data + HIGHFLOWNEXT_POWER) * 1000000; + + priv->voltage_input[0] = get_unaligned_be16(data + HIGHFLOWNEXT_5V_VOLTAGE) * 10; + priv->voltage_input[1] = + get_unaligned_be16(data + HIGHFLOWNEXT_5V_VOLTAGE_USB) * 10; + + priv->speed_input[0] = get_unaligned_be16(data + HIGHFLOWNEXT_FLOW); + priv->speed_input[1] = get_unaligned_be16(data + HIGHFLOWNEXT_WATER_QUALITY); + priv->speed_input[2] = get_unaligned_be16(data + HIGHFLOWNEXT_CONDUCTIVITY); + break; default: break; } @@ -851,6 +922,19 @@ static int aqc_probe(struct hid_device *hdev, const struct hid_device_id *id) priv->voltage_label = label_fan_voltage; priv->current_label = label_fan_current; break; + case USB_PRODUCT_ID_HIGHFLOWNEXT: + priv->kind = highflownext; + + priv->num_fans = 0; + priv->num_temp_sensors = HIGHFLOWNEXT_NUM_SENSORS; + priv->temp_sensor_start_offset = HIGHFLOWNEXT_SENSOR_START; + priv->power_cycle_count_offset = QUADRO_POWER_CYCLES; + + priv->temp_label = label_highflownext_temp_sensors; + priv->speed_label = label_highflownext_fan_speed; + priv->power_label = label_highflownext_power; + priv->voltage_label = label_highflownext_voltage; + break; default: break; } @@ -907,6 +991,7 @@ static const struct hid_device_id aqc_table[] = { { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_FARBWERK360) }, { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_OCTO) }, { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_QUADRO) }, + { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_HIGHFLOWNEXT) }, { } }; |