DMA: fix AMBA PL08x compilation issue with 64bit DMA address type
When dma_addr_t is 64 bits long, compilation of the AMBA PL08x DMA driver breaks due to a missing 64bit%8bit modulo operation. Looking more closely the divisor in these operations can only be 1, 2 or 4, so the full featured '%' modulo operation is overkill and can be replaced with simple bit masking. Change from v1: Replace open-coded function with existing IS_ALIGNED macro and use a macro around that to avoid a line becoming too long. Signed-off-by: Andre Przywara <andre.przywara@linaro.org> Acked-by: Vinod Koul <vinod.koul@intel.com> Signed-off-by: Rob Herring <rob.herring@calxeda.com>
Diffstat (limited to 'drivers/dma/amba-pl08x.c')
-rw-r--r--drivers/dma/amba-pl08x.c14
1 files changed, 8 insertions, 6 deletions
diff --git a/drivers/dma/amba-pl08x.c b/drivers/dma/amba-pl08x.c
index 06fe45c74de5..fb3ce9eefca7 100644
--- a/drivers/dma/amba-pl08x.c
+++ b/drivers/dma/amba-pl08x.c
@@ -133,6 +133,8 @@ struct pl08x_bus_data {
u8 buswidth;
};
+#define IS_BUS_ALIGNED(bus) IS_ALIGNED((bus)->addr, (bus)->buswidth)
+
/**
* struct pl08x_phy_chan - holder for the physical channels
* @id: physical index to this channel
@@ -886,8 +888,8 @@ static int pl08x_fill_llis_for_desc(struct pl08x_driver_data *pl08x,
return 0;
}
- if ((bd.srcbus.addr % bd.srcbus.buswidth) ||
- (bd.dstbus.addr % bd.dstbus.buswidth)) {
+ if (!IS_BUS_ALIGNED(&bd.srcbus) ||
+ !IS_BUS_ALIGNED(&bd.dstbus)) {
dev_err(&pl08x->adev->dev,
"%s src & dst address must be aligned to src"
" & dst width if peripheral is flow controller",
@@ -908,9 +910,9 @@ static int pl08x_fill_llis_for_desc(struct pl08x_driver_data *pl08x,
*/
if (bd.remainder < mbus->buswidth)
early_bytes = bd.remainder;
- else if ((mbus->addr) % (mbus->buswidth)) {
- early_bytes = mbus->buswidth - (mbus->addr) %
- (mbus->buswidth);
+ else if (!IS_BUS_ALIGNED(mbus)) {
+ early_bytes = mbus->buswidth -
+ (mbus->addr & (mbus->buswidth - 1));
if ((bd.remainder - early_bytes) < mbus->buswidth)
early_bytes = bd.remainder;
}
@@ -928,7 +930,7 @@ static int pl08x_fill_llis_for_desc(struct pl08x_driver_data *pl08x,
* Master now aligned
* - if slave is not then we must set its width down
*/
- if (sbus->addr % sbus->buswidth) {
+ if (!IS_BUS_ALIGNED(sbus)) {
dev_dbg(&pl08x->adev->dev,