diff options
author | Prashanth Prakash <pprakash@codeaurora.org> | 2018-04-04 21:14:51 +0300 |
---|---|---|
committer | Rafael J. Wysocki <rafael.j.wysocki@intel.com> | 2018-04-24 13:33:28 +0300 |
commit | 6fa12d584dcba18f67425ce17e9317311a624f81 (patch) | |
tree | deeea62992f02ba49125e04a198e136c9c487122 /drivers/cpufreq/cppc_cpufreq.c | |
parent | 4773e77cdc9b3af93ee1ae7bcf2acf94fde17166 (diff) | |
download | linux-6fa12d584dcba18f67425ce17e9317311a624f81.tar.xz |
ACPI / CPPC: Check for valid PCC subspace only if PCC is used
Changes the behavior where we return error if there are no valid PCC
subspace for a given performance domain.
The ACPI spec does not mandate the use PCC, so it is possible to have
platforms where a PCC subspace may not be present, so we need to check
for a valid PCC subspace ID only if the register is a PCC register.
Signed-off-by: Prashanth Prakash <pprakash@codeaurora.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Diffstat (limited to 'drivers/cpufreq/cppc_cpufreq.c')
0 files changed, 0 insertions, 0 deletions