clk: ux500: Provide device enumeration number suffix for SMSC911x
First Ethernet device has a ".0" appended onto the device name. It
appears that we need this in order to obtain the correct clock.
Without this fix Ethernet does not function on Ux500 devices, which is a
regression.
Cc: Ulf Hansson <ulf.hansson@linaro.org>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
[mturquette@linaro.org: improved changelog]
Diffstat (limited to 'drivers/clk')
-rw-r--r-- | drivers/clk/ux500/u8500_clk.c | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/clk/ux500/u8500_clk.c b/drivers/clk/ux500/u8500_clk.c index 0b4f35a5ffc2..80069c370a47 100644 --- a/drivers/clk/ux500/u8500_clk.c +++ b/drivers/clk/ux500/u8500_clk.c @@ -325,7 +325,7 @@ void u8500_clk_init(u32 clkrst1_base, u32 clkrst2_base, u32 clkrst3_base, clk = clk_reg_prcc_pclk("p3_pclk0", "per3clk", clkrst3_base, BIT(0), 0); clk_register_clkdev(clk, "fsmc", NULL); - clk_register_clkdev(clk, NULL, "smsc911x"); + clk_register_clkdev(clk, NULL, "smsc911x.0"); clk = clk_reg_prcc_pclk("p3_pclk1", "per3clk", clkrst3_base, BIT(1), 0); |