summaryrefslogtreecommitdiff
path: root/drivers/acpi
diff options
context:
space:
mode:
authorRafael J. Wysocki <rafael.j.wysocki@intel.com>2020-02-28 00:51:36 +0300
committerRafael J. Wysocki <rafael.j.wysocki@intel.com>2020-02-28 00:51:36 +0300
commitc823c17a8ea4db4943152388a0beb9a556715716 (patch)
treea445c542e7296d2c75448c1ffb8ebbf81bcbe258 /drivers/acpi
parentf8788d86ab28f61f7b46eb6be375f8a726783636 (diff)
downloadlinux-c823c17a8ea4db4943152388a0beb9a556715716.tar.xz
ACPI: EC: Avoid printing confusing messages in acpi_ec_setup()
It doesn't really make sense to pass ec->handle of the ECDT EC to acpi_handle_info(), because it is set to ACPI_ROOT_OBJECT in acpi_ec_ecdt_probe(), so rework acpi_ec_setup() to avoid using acpi_handle_info() for printing messages. First, notice that the "Used as first EC" message is not really useful, because it is immediately followed by a more meaningful one from either acpi_ec_ecdt_probe() or acpi_ec_dsdt_probe() (the latter also includes the EC object path), so drop it altogether. Second, use pr_info() for printing the EC configuration information. While at it, make the code in question avoid printing invalid GPE or IRQ numbers and make it print the GPE/IRQ information only when the driver is ready to handle events. Fixes: 72c77b7ea9ce ("ACPI / EC: Cleanup first_ec/boot_ec code") Fixes: 406857f773b0 ("ACPI: EC: add support for hardware-reduced systems") Cc: 5.5+ <stable@vger.kernel.org> # 5.5+ Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Diffstat (limited to 'drivers/acpi')
-rw-r--r--drivers/acpi/ec.c15
1 files changed, 10 insertions, 5 deletions
diff --git a/drivers/acpi/ec.c b/drivers/acpi/ec.c
index d1f1cf5d4bf0..2dc7cf2aeb21 100644
--- a/drivers/acpi/ec.c
+++ b/drivers/acpi/ec.c
@@ -1584,14 +1584,19 @@ static int acpi_ec_setup(struct acpi_ec *ec, struct acpi_device *device,
return ret;
/* First EC capable of handling transactions */
- if (!first_ec) {
+ if (!first_ec)
first_ec = ec;
- acpi_handle_info(first_ec->handle, "Used as first EC\n");
+
+ pr_info("EC_CMD/EC_SC=0x%lx, EC_DATA=0x%lx\n", ec->command_addr,
+ ec->data_addr);
+
+ if (test_bit(EC_FLAGS_EVENT_HANDLER_INSTALLED, &ec->flags)) {
+ if (ec->gpe >= 0)
+ pr_info("GPE=0x%x\n", ec->gpe);
+ else
+ pr_info("IRQ=%d\n", ec->irq);
}
- acpi_handle_info(ec->handle,
- "GPE=0x%x, IRQ=%d, EC_CMD/EC_SC=0x%lx, EC_DATA=0x%lx\n",
- ec->gpe, ec->irq, ec->command_addr, ec->data_addr);
return ret;
}