summaryrefslogtreecommitdiff
path: root/drivers/acpi/Kconfig
diff options
context:
space:
mode:
authorDmitry Torokhov <dmitry.torokhov@gmail.com>2013-05-01 19:47:44 +0400
committerDmitry Torokhov <dmitry.torokhov@gmail.com>2013-05-01 19:47:44 +0400
commitbf61c8840efe60fd8f91446860b63338fb424158 (patch)
tree7a71832407a4f0d6346db773343f4c3ae2257b19 /drivers/acpi/Kconfig
parent5846115b30f3a881e542c8bfde59a699c1c13740 (diff)
parent0c6a61657da78098472fd0eb71cc01f2387fa1bb (diff)
downloadlinux-bf61c8840efe60fd8f91446860b63338fb424158.tar.xz
Merge branch 'next' into for-linus
Prepare first set of updates for 3.10 merge window.
Diffstat (limited to 'drivers/acpi/Kconfig')
-rw-r--r--drivers/acpi/Kconfig30
1 files changed, 20 insertions, 10 deletions
diff --git a/drivers/acpi/Kconfig b/drivers/acpi/Kconfig
index 119d58db8342..92ed9692c47e 100644
--- a/drivers/acpi/Kconfig
+++ b/drivers/acpi/Kconfig
@@ -176,11 +176,16 @@ config ACPI_FAN
config ACPI_DOCK
bool "Dock"
- depends on EXPERIMENTAL
help
This driver supports ACPI-controlled docking stations and removable
drive bays such as the IBM Ultrabay and the Dell Module Bay.
+config ACPI_I2C
+ def_tristate I2C
+ depends on I2C
+ help
+ ACPI I2C enumeration support.
+
config ACPI_PROCESSOR
tristate "Processor"
select THERMAL
@@ -196,7 +201,7 @@ config ACPI_PROCESSOR
the module will be called processor.
config ACPI_IPMI
tristate "IPMI"
- depends on EXPERIMENTAL && IPMI_SI && IPMI_HANDLER
+ depends on IPMI_SI && IPMI_HANDLER
default n
help
This driver enables the ACPI to access the BMC controller. And it
@@ -208,14 +213,13 @@ config ACPI_IPMI
config ACPI_HOTPLUG_CPU
bool
- depends on EXPERIMENTAL && ACPI_PROCESSOR && HOTPLUG_CPU
+ depends on ACPI_PROCESSOR && HOTPLUG_CPU
select ACPI_CONTAINER
default y
config ACPI_PROCESSOR_AGGREGATOR
tristate "Processor Aggregator"
depends on ACPI_PROCESSOR
- depends on EXPERIMENTAL
depends on X86
help
ACPI 4.0 defines processor Aggregator, which enables OS to perform
@@ -261,6 +265,16 @@ config ACPI_CUSTOM_DSDT
bool
default ACPI_CUSTOM_DSDT_FILE != ""
+config ACPI_INITRD_TABLE_OVERRIDE
+ bool "ACPI tables override via initrd"
+ depends on BLK_DEV_INITRD && X86
+ default n
+ help
+ This option provides functionality to override arbitrary ACPI tables
+ via initrd. No functional change if no ACPI tables are passed via
+ initrd, therefore it's safe to say Y.
+ See Documentation/acpi/initrd_table_override.txt for details
+
config ACPI_BLACKLIST_YEAR
int "Disable ACPI for systems before Jan 1st this year" if X86_32
default 0
@@ -293,7 +307,7 @@ config ACPI_DEBUG_FUNC_TRACE
is about half of the penalty and is rarely useful.
config ACPI_PCI_SLOT
- tristate "PCI slot detection driver"
+ bool "PCI slot detection driver"
depends on SYSFS
default n
help
@@ -302,9 +316,6 @@ config ACPI_PCI_SLOT
i.e., segment/bus/device/function tuples, with physical slots in
the system. If you are unsure, say N.
- To compile this driver as a module, choose M here:
- the module will be called pci_slot.
-
config X86_PM_TIMER
bool "Power Management Timer Support" if EXPERT
depends on X86
@@ -322,8 +333,7 @@ config X86_PM_TIMER
systems require this timer.
config ACPI_CONTAINER
- tristate "Container and Module Devices (EXPERIMENTAL)"
- depends on EXPERIMENTAL
+ bool "Container and Module Devices"
default (ACPI_HOTPLUG_MEMORY || ACPI_HOTPLUG_CPU || ACPI_HOTPLUG_IO)
help
This driver supports ACPI Container and Module devices (IDs